– 40 –
(10) Adjustment of needle stop position
1) Adjustment of upper stop position (Stop position after thread trimming)
2) Adjustment of lower stop position
B
A
C
D
Standard Adjustment
Setup No.
Functions
Standard
Setting range
121
Upper needle stop position
0
–15 to 15
122
Lower needle stop position
0
–15 to 15
E