Installation and operating instructions: JUDO UV disinfection system JUV 10-110 G/GS
All rights reserved.
JUDO Wasseraufbereitung GmbH
© JUDO Wasseraufbereitung GmbH
Postfach 380
D-71351 Winnenden
Translation into foreign languages and reproduction, even in excerpt form, is only permitted with special
approval.
Tel. +49 (0)7195-692-0
Fax +49 (0)7195-692-188
Revision level: 03.05.2017
E-mail: [email protected]
Internet: www.judo.eu
14
4.3
Technical data
Performance data
JUV G/GS
10
20
35
50
60
110
Max. flow *
(at 400 J/m² UV dose)
m³/h
0.84
1.8
3.3
4.8
6.0
11.0
Mechanical, hydraulic data
Pipe connection input/output
"
¾ external
thread
1 external
thread
1½ external thread
Drain connection
(to the drain)
"
○
½ external thread
Vent connection
"
○
⅛ external thread
Dimensions, control unit
(WxHxD)
mm
215 x 215 x 90
Maximum permissible operating pressure
bar
9
Admissible medium temperature
°C
5 - 40
Maximum permissible ambient temperature °C
35
Electrical data
Power supply
(via power plug)
VAC
230 ± 10 %
Frequency
Hz
50/60
Internal device fuse
(5x20 mm)
A
3.15 T
Power consumption
W
33
44
44
88
88
177
UVC lamp wattage
W
30
40
40
80
40
80
Number of UVC lamps
1
2
Theoretical life of UVC lamp **
h
9000
Maximum contact load of relay contact
VAC/A
230/2
Remote input
VDC
5
Control unit, degree of protection
(closed
housing cover)
IP 55
Radiation chamber protection type
IP 54
Weights and volumes
Radiation chamber (approx.)
(empty weight)
kg
1.5
2.5
6
6
8
8
Control unit approx.
kg
1
Approx. radiation chamber volume
l
1
1.8
7.9
7.9
7.6
7.6
Tab. 5: Technical data
* As compared to 96% UV transmission based on a layer thickness of 1 cm
In the case of different flow rates, temperatures or water qualities, the values are
different (technical advice necessary).
** May be significantly low depending on the operating conditions and water quality.