10 Faults
Fault
Cause
Remedy
LED alarm and display
LOW UVC %
Dirty quartz tube and/or UV sensor
surface
Clean quartz tube and/or UV sensor surface
UV transmission of water too low,
changed water parameters
Technical advice necessary
LED alarm and display
HIGH TEMPER.
Air in radiation chamber
Vent radiation chamber
Flow interrupted or too low
Ensure proper flow
UV radiation strength
illogical
Air in radiation chamber
Vent radiation chamber
UVC lamp does not ignite
Water temperature < 5 °C
Ensure required water temperature
Tab. 10: Mechanical or hydraulic faults
Fault
Cause
Remedy
Control unit not working
Power failure
Check site-provided fuse
Device fuse blown
Replace device fuse
Control unit faulty and/or defective. Check control unit, replace as necessary
(JUDO customer service)
UVC lamp does not ignite
Connecting cable faulty
Check connecting cable, replace if necessary
UVC lamp faulty and/or defective
Check UVC lamp, replace if necessary (JUDO
customer service)
Ballast or ignition device and/or
heating transformer faulty or
defective
Replace control unit
(JUDO customer service)
Power supply
< 200VAC
Ensure required power supply.
LED alarm and display
LAMP OFF
UVC lamp faulty and/or defective
Check UVC lamp, replace if necessary (JUDO
customer service)
LED alarm and display
CHANGE LAMPS
UVC lamp life expired
Replace UVC lamp, reset countdown (JUDO
customer service)
LED alarm and display
LOW UVC %
UVC lamp life expired
Replace UVC lamp, reset countdown (JUDO
customer service)
Quartz tube dirty
Clean quartz tube (JUDO customer service)
UV sensor surface dirty
Clean UV sensor (JUDO customer service)
LED alarm
UV sensor faulty and/or defective
Check UVC sensor, replace if necessary
(JUDO customer service)
UV radiation strength
illogical
Power supply fluctuations
Check power supply
External sensor signal fault or
electronics fault
Check surrounding electrical installations (e.g.
frequency converter, etc.)
Tab. 11: Electrical faults