JUDO BIOSTAT 25 TGA
9
Product information
3.
Product information
3.1
Intended purpose
This water treatment device is suitable for
use in cold drinking water up to a maximum
water temperature of 86 °F (30 °C).
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
Please refer to the chapter “Intended use”
for use restrictions.
This water treatment device reduces the
tendency of the water to precipitate out
excess calcium and thus protects the water-
pipes and water heaters from lime deposits.
Appliances and taps are protected.
3.2
Test marks
The devices conform to the technical regula-
tions for drinking water installations in accor-
dance with the German standard DIN 1988.
They comply with the requirements of the
work sheet W 510 (lime protection devices
for use in drinking water installations) issued
by the DVGW (Deutsche Vereinigung des
Gas- und Wasserfaches e.V.), the German
technical-scientific association for the gas
and water industries, and are entitled to bear
the DVGW mark (see fig. 3).
3.3
Materials used
The materials used are resistant to the
physical, chemical and corrosive loads to be
expected in the drinking water. All materials
are hygienically and physiologically safe.
Plastics fulfill the official guideline of the
German Federal Environmental Agency as
well as the work sheet W 270 issued by the
DVGW. Metallic materials fulfil the require-
ments of the German standard DIN 50930-6
(influence on drinking water condition).
4.
Installation
4.1
General
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
The unit may only be installed by skilled
personnel.
The chapter “Intended use” has always to be
observed !
The pipes must be able to support in a safe
way the water treatment device.
Otherwise mechanical damage or fractures/
bursts can occur in the pipes. This can result
in major water damage. People close to the
water treatment device are exposed to a
health risk due to the large quantities of
water released. Therefore, if necessary, the
pipes must be additionally fixed or
supported.
Always observe the given spacings to
ensure convenient operation and servicing
(see chapter “Mounting dimensions”).
A distance of at least 6 inch (150 mm) above
and below the water treatment device
is required in order to be able to carry out
properly all the maintenance and servicing
work.
Lime deposits restrain the water
flow and can therefore lead to an
increased energy consumption.
Fig. 3:
DVGW mark