18
JUDO BIOSTAT 25 TGA
Maintenance
6.3
Warning message "Battery
low"
To ensure that cleaning / flushing is carried
out completely, even in case of a power
failure, the water treatment device has a 9 V
block battery installed as an emergency
power supply.
Before each cleaning / flushing a battery test
will be effected. A missing, unloaded or
defective battery is indicated by the flashing
of the red LED 4. A trigging of the container
flushing is then not possible.
6.4
Mounting of the panelling
Dismantling:
–
Withdraw the upper / inferior clamping
fixture.
–
Carefully pull apart the right and the left
panel parts by the handle cavities on
the back of the panelling.
–
Remove the type plate and the panel-
ling.
Assembly:
–
Push the right and left parts of the panel-
ling together till a gap of approximately
0.6 inch (15 mm) is left.
–
Ensure that the cable is not trapped!
–
Refit the type plate in the blanks, of the
panelling, situated above and below.
–
Push the panelling completely together.
Disconnect the power supply
from the socket.
Plug the power supply into
the socket!