14
JUDO BIOSTAT-COMBIMAT
Operation
5.2
Setting the flushing interval
Factory-provided setting
: 5 m³
(see chapter “Cleaning/flushing”)
–
Unplug the power supply from the socket.
–
Disassemble the cover caps of the water
treatment device (see chapter “Mounting
the cover caps”).
–
Set the flushing interval via the contacts
1 to 4 of the DIP switch.
For setting only one contact, 1 to 4, may be
moved to the left side.
To incorrect settings the electrical circuit
responds with an acoustic signal (see chap-
ter “Fault”).
–
Assemble the cover caps of the water
treatment device again (see chapter
“Mounting the cover caps”).
–
Reconnect the power supply to the
socket!
5.3
Setting the hygiene unit
For an optimal function of the hygiene unit
the electrical circuit is set corresponding to
the chloride content of the mains water. The
chloride content of the mains water can be
requested at the responsible water works.
Alternatively a sample of water can be sent
to our customer service for determining the
chloride content (see chapter “Customer
support / Service clientèle”).
–
Unplug the power supply from the socket.
–
Disassemble the cover caps of the water
treatment device (see chapter “Mounting
the cover caps”).
–
Set the chloride content via the contacts
5 and 6 of the DIP switch.
To incorrect settings the electrical circuit
responds with an acoustic signal (see chap-
ter “Fault”).
–
Assemble the cover caps of the water
treatment device again (see chapter
“Mounting the cover caps”).
–
Reconnect the power supply to the
socket!
5 m³
10 m³
20 m³
40 m³
Tab. 1: Setting the flushing interval at the DIP switch
1
2
3
4
5
6
7
8
OPEN
1 2
3 4 5
6 7 8
OPEN
1 2
3 4
5
6 7 8
OPEN
1 2
3 4
5
6 7 8
OPEN
0 bis
60 mg/l
60 bis
120 mg/l
120 bis
180 mg/l
180 bis
250 mg/l
Tab. 2: Setting the hygiene unit at the DIP switch