18
JUDO BIOSTAT-COMBIMAT
Operation
5.9
Replacing the batteries
When a change of batteries is required
(LED 3 flashes) the following procedure is
adopted:
–
Disconnect the power supply from the
socket.
–
Remove the covers from the water treat-
ment device.
The battery is located behind the electrical
switch and must be disconnected from the
battery clip.
–
Exchange the battery and push it back
into the corresponding blank behind the
switch.
–
Remount the covers on the water treat-
ment device.
–
Plug the power supply into the socket!
Battery disposal:
5.10 Modifications / changes /
spare parts
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
Only original spare parts are to be used!
For safety reasons, it is forbidden to carry
out unauthorized modifications on this unit!
These may not only impair the function of
the unit itself, but also lead to leaks and
bursting!
The test marks imprinted on the unit are only
valid if original spare parts are used.
5.11 Stoppages
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
If a water treatment device has to be
removed from the flange or unscrewed, the
chapter “Intended use” must always be
observed!
–
Protect the flange surfaces from
damage! Damaged flanged surfaces
cannot close tight. As a result, escaping
water can damage the building and
installations.
–
Ensure that no dirt can get into the water
treatment device! This dirt can get into
contact with and be discharged into the
drinking water when the water treatment
device is switched back on. The health
of people who drink dirty water is at risk.
–
Store the water treatment device in frost-
free environment! Frost can cause any
water contained in the water treatment
device voids to freeze and thus cause
mechanical damage to the water treat-
ment device so that it leaks at operating
pressure or can burst. Leaking water can
cause major damage to the building. In
addition, people near the water treat-
ment device can be injured by breaking
off water treatment device parts.
–
When restarting the water treatment
device, follow the instructions for a new
water treatment device.
Only use 9 V alkaline type block
batteries (see battery description).
Return run-down batteries to a
distributor or to a properly authorised
local disposal return point.