background image

H0590700.B - 2016/08

Instructi ons for installati on and use

English

More documents on:

www.zodiac-poolcare.com

EN

Summary of Contents for CS Series

Page 1: ...H0590700 B 2016 08 Instructions for installation and use English More documents on www zodiac poolcare com EN...

Page 2: ...er by recorded delivery letter In the event of a device containing coolant that tipping over state your reservations to the carrier in writing If the appliance su ers a malfunction do not try to repai...

Page 3: ...the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injury and will void the warranty Save theses instructions during the de...

Page 4: ...seal x 2 E 63 50 mm dia union x 1 1 2 I Technical speci cations Unit CS 100 CS 150 Operating water temperature 1 to 40 C Filter area m 9 3 14 0 Maximum ow m h 22 7 28 4 Filtration speed m h m 2 4 2 1...

Page 5: ...0 370 470 80 510 330 510 360 Water intake Water outlet Draining Pressure gauge Air release Clamp ring dimensions in mm Front Top 1 4 I Graphs showing loss of head depending on ow rate 0 0 6 1 2 1 8 2...

Page 6: ...s could damage the lter It should be easily accessible for doing work cover hydraulic connections draining Allow total vertical clearance of at least 1 35 m in order to be able to open the lter and re...

Page 7: ...d discharge if it is installed below the water level Avoid high points on the pipework for more e cient priming Check that the hydraulic couplings are correctly tightened and that there are no leaks P...

Page 8: ...cover must be correctly tightened and its seal clean and in place on the clamping ring inside the cover If necessary apply a silicone based lubricant to facilitate installation Check that the hydraul...

Page 9: ...se operations are carried out by a technician and are chargeable 4 2 1 User maintenance Clean the outside of the equipment do not use solvent based products Check the lter pressure and the condition o...

Page 10: ...ensure that the bleed pipe is properly located inside it see para 4 2 3 Cleaning or replacing the lter cartridge Check the condition of the seal on the clamp ring inside the cover Replace it if it is...

Page 11: ...see para 4 2 3 Cleaning or replacing the lter cartridge The pump is not running quickly enough Adjust the pump speed to achieve a su cient ow variable speed pump only The water level in the pool is t...

Page 12: ...49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Trouvez plus d...

Reviews: