- 20 -
f."ON / OFF" key: the key is designed for "on / off" screen operation. Just press the
"ON / OFF" button, you can turn on the 15.6-inch HD LCD PANEL (green indicator
lights, which indicates that the display is already turned on), or Press the "ON / OFF" to
turn off the 15.6-inch HD LCD PANEL (green indicator goes out, which indicated that
the display has been turned off).
(
Figure 3.1.2
)
(2)Power module
The power module of ground control station is composed of power supply part and
charging part.
The power supply part is powered by the lithium battery of 20000mAh. You just need to
connect the female of lithium battery XH-6P, and the positive pole (red line) and
negative electrode (black line) of lithium battery to the male, red line and black line of
XH-6P inside the ground control station correspondingly, the ground control station can
be started with one button through the metal switch on the panel.
The interface of charging part is composed of XH2.54mm 6P socket and XT 60 plug,
and the lithium battery inside the ground control station can be charged through the
charging interface on the panel, or it can be charged through the adapter by removing
the lithium battery.
Note: it is suggested that, when the ground control station isn't used, take out the
battery and store it in the battery box, and keep it in low-voltage state. Make sure that
the battery is fully charged before use.