4. Loading and Unloading Terminals
4-1
Loading Terminals Into The Applicator
4-1-1 Turn presses power off and disconnect from receptacle.
4-1-2 Rotate the wing bolt on the pressure plate clockwise to raise the pressure plate.
Wing Bolt
4-1-3
Feed the terminal strip under the pressure plate and through the guide plates until the first
terminal is centered over the crimp anvils.
Centered over anv
il