5.OPERATION OF TARGET TRACKING AND AIS
>
5.5 ALARM DISPLAY
5.5
ALARM DISPLAY
Critical alarm messages for Target Tracking (TT) and AIS functions:
Alarm messages for Target Tracking (TT) and AIS functions:
Error message and alarm are displayed in the lower right of the display.
See also Section 9.1.1 "List of Alarms and other Indications".
Error message
Description
CPA/TCPA
There is a dangerous target. See also Section 5.5.1.
Error message
Description
CPA/TCPA
There is a dangerous target.
New Target
A new target is acquired in the automatic acquisition zone.
Lost
There is a lost target.
REF Target
The accuracy of the reference target may be decreased.
95% Capacity
The number of targets being tracked by the Target Tracking
function has reached 95% of the maximum.
MAX Target
The number of targets being tracked by the Target Tracking
function has reached the maximum.
AIS 95% Capacity
The number of displayed AIS target symbols has reached 95%
of the maximum.
AIS MAX Target
The number of received data items exceeds the maximum
number of AIS target symbols that can be displayed.
AIS ACT 95% Capacity The number of activated AIS targets by the AIS function has
reached 95% of the maximum.
AIS ACT MAX
The number of activated AIS targets by the AIS function has
reached the maximum.
AIS Alarm ***
Alarm information issued with the ALR sentence by the AIS.
*** is a 3-digit number which is Local Alarm No in the ALR
sentence. See below:
AIS Alarm 001
Tx malfunction
AIS Alarm 002
Antenna VSWR exceeds limit
AIS Alarm 003
Rx channel 1 malfunction
AIS Alarm 004
Rx channel 2 malfunction
AIS Alarm 005
Rx channel 70 malfunction
AIS Alarm 006
general failure
AIS Alarm 008
MKD connection lost
AIS Alarm 025
external EPFS lost
AIS Alarm 026
no sensor position in use
AIS Alarm 029
no valid SOG information
AIS Alarm 030
no valid COG information
AIS Alarm 032
Heading lost/invalid
AIS Alarm 035
no valid ROT information
Summary of Contents for JMA-7110-6XA
Page 2: ......
Page 19: ...xvii NQE 3141 4A 8A Interswitch Unit NQE 3167 Power Control Unit Warning Label Warning Label...
Page 26: ...xxiv Display Unit Type NCD 4790 Stand alone type Interswitch Unit Type NQE 3141 4A...
Page 44: ......
Page 46: ......
Page 48: ......
Page 84: ......
Page 120: ......
Page 250: ......
Page 334: ......
Page 350: ...6 16 JMA 7100 Instruction Manual 6 TRUE AND FALSE ECHOES ON DISPLAY 6 6 DISPLAY OF AIS SART...
Page 440: ......
Page 458: ......
Page 462: ...10 4 JMA 7100 Instruction Manual 10 DISPOSAL 10 5 ABOUT THE CHINA ROHS...
Page 488: ......
Page 545: ...JMA 7100 Instruction Manual B DRAWINGS B 8 GYRO I F B 43 B TableB 2 Gyro Log Settings...
Page 550: ...B 48 JMA 7100 Instruction Manual B DRAWINGS B 9 Inter Switch Unit...
Page 552: ......
Page 569: ...JMA 7100 Instruction Manual C Menu Index C 9 Serviceman Menu C 17 C...
Page 570: ...C 18 JMA 7100 Instruction Manual C Menu Index C 9 Serviceman Menu...
Page 571: ......