Jøtul GF 200 DV IPI Installation And Operation Instructions Manual Download Page 4

4

139587_05  GF 200 DV IPI  October 2015

18”

457 mm

21 7/16”

544 mm

26 13/16”

681 mm

22”

559 mm

152 mm

17 3/16”

437 mm

15 1/16”

383 mm

22 3/4”

578 mm

18”

457 mm

13 5/8”

321 mm

25”

635  mm

9 5/16”

237 mm

4 3/16”

106 mm

5/8 Venting off Rear

4/6 Venting to Vertical

GF 

200

 DV IPI  

Specifications

Input Rates

Natural Gas 

   20,000 BTU/hr. maximum input 

11,000 BTU/hr. minimum input

Propane

 

 18,000 BTU/hr. maximum input 

9,000 BTU/hr. minimum input

Inlet Pressure:

            MIN    MAX 

Natural Gas:    

 5.0 WC  (1.25 kPa)     7.0 WC  (1.74 kPa)

Propane:        

12.0 WC  (3.0 kPa)    14.0 WC  (3.48 kPa)

Manifold Pressure:

       MIN  

 

MAX 

Natural Gas:    

1.1 WC (.27 kPa)         3.80 WC  (.95 kPa)

Propane:          

2.9 WC (.72 kPa)          11.0  WC  (2.74 kPa)  

 

 

•   SIT Prof lame 1 Intermitent Pilot Ignition - 120V / 60 Hz

  •   Steady State Efficiency:  72.92% NG / 73.09% LP

 •  AFUE Efficiency:  68.6%  NG   /   68.2 %  LP
•  CSA P4. 1-02 Fireplace Efficiency:  

       NG - 69.11%      LP - 68.97%

•  Factory Air Shutter Settings: NG - 1/16”     LP - 1/8” 
•  Continuous Pilot Ignition  Mode (CPI) is available
 •  Power Requirement:  120 VAC 

  AC/DC Power Adaptor, High Temperature / 7V 

  Back-up Battery Pack:  4,  AA - 1.5V

•  Ambient Temperature Range:  32 -122°F  (0 - 50°C) 

Unpacking your stove 

  CAUTION: Enamelled parts may be damaged if handled 

without care. Use assistants to position the stove. 

Place removed parts on a towel or other protective 

material.

1.  FAMILIARIZE YOURSELF WITH THE VENTING, CLEARANCE 

AND OTHER INSTALLATION REQUIREMENTS IN THIS 

MANUAL BEFORE BEGINNING THE INSTALLATION.

2. 

SAFETY BARRIER SCREEN:  This appliance is equipped 

with a Certified Barrier Screen that must be installed 

before operating the unit. 

It is secured to the shipping 

pallet.

 

Remove two screws and break the attachment 

bracket off of the frame at the perforation. The barrier 

assembly attaches to the stove front by engaging its 

brackets over the stove door hinge bosses.  The barrier 

may be installed with the stove doors either open or 

closed. 

3.  Remove the Top Plate of the stove by simply lifting it 

straight off of the stove body. 

4.  To open the firebox, disengage the two Glass Frame 

Latches located on top of the firebox. Pull each handle 

forward to clear the latch from the notch in the frame 

and lift the frame straight up out of the stove.

5.  Connect the battery box wire leads to the black and 

red DFC harness connectors under the back of the 

stove.  Tuck the connected wire harness up into the 

slot on the DFC bracket as shown in Fig 47, page 24. 

Install the backup batteries into the battery box and 

attach the box to the hook and loop tape on the 

bottom of the gas valve. See fig. 48a on page 25.  

6.  Connect the AC/DC Power Adaptor to the terminal on 

the left of the DFC module mounting bracket as shown 

in Fig. 48a. Connect the power adaptor to 110 VAC 

house current.

7.  INSTALL ACCESSORIES BEFORE LOCATING THE STOVE 

IN ITS FINAL POSITION. Follow the instructions in this 

manual or those included with the accessory items.

Height Dimensions with Optional Long Legs: 

 - add 2 1/4 in. (57 mm)

Safety Screen 

Barrier

Summary of Contents for GF 200 DV IPI

Page 1: ...department Installation and service must be performed by a qualified installer service agency or the gas supplier In the Commonwealth of Massachusetts a carbon monoxide CO detector shall be installed...

Page 2: ...ed by code Tee joint Pipe wrench Pipe sealant 10 mm open end wrench 1 2 7 16 open end wrench Phillips head screwdriver Flat head screwdriver 1 4 nut driver Gloves Safety glasses Torx T 20 screwdriver...

Page 3: ..._________ INSTALLER __________________________________ FUEL TYPE ____________________________________ FUEL CONVERSION NO _______ YES______ INTALLATION DATE _____________________________ INSTALLATION T...

Page 4: ...ORE BEGINNINGTHE INSTALLATION 2 SAFETY BARRIER SCREEN This appliance is equipped with a Certified Barrier Screen that must be installed before operating the unit It is secured to the shipping pallet R...

Page 5: ...ation Code current edition DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER Call a qualified service technician to inspect the heater and to replace any part of the con trol system and any g...

Page 6: ...tly on carpeting vinyl linoleum or wood laminate flooring such as Pergo If this appliance will be installed on any combustible material OTHER THAN WOOD a floor pad must be in stalled that is either me...

Page 7: ...5 5 5 Max Mantel Depth Min Mantel Depth Max Top Trim Depth 1 3 5 Max 6 1 2 A 51 1 2 in 1308 mm B 50 in 1270 mm C 48 1 2 in 1232 mm D 47 in 1194 mm Figure 4 Minimum Alcove Clearances Figure 2 Parallel...

Page 8: ...or failure to meet all clearance requirements will void all warranties and could result in property damage bodily injury or serious fire The approved vent configurations described in this manual are d...

Page 9: ...re 8 Use 1 4 socket driver to loosen the Exhaust Restrictor dial and adjust as appropriate for your termination zone Figure 9 Vent Termination Zone Matrix NG LP NOTE 4 6 VENT MAXIMUM RUN DIRECTLY OFF...

Page 10: ...ly for your particular installation See also figs 10 12 Figure 11 Remove the Primary Baffle from Secondary Baffle Secondary Baffle Primary Baffle Secondary Baffle Use Fig 11 Fuel Termination Vent Inst...

Page 11: ...t of the vent may alleviate these conditions Use Wall Straps to support an offset pipe run at intervals of three feet to avoid excessive stress on the offsets Elbows Four 45 or two 90 elbows may be us...

Page 12: ...PIPE MUST EXTEND 6 FEET BEYOND THE DAMPER AREA OF THE FIREPLACE If the intake flex duct does not extend the full length of the chimney and connect to both the unit and the termination cap A METAL BLO...

Page 13: ...t pipe Use 4 6 Vent Adaptor Kit 157674 See figs 13 14 Use the guidelines for vertical termination shown on page 11 In masonry chimney a fireclay liner or listed steel liner must be present the entire...

Page 14: ...rance from projections exceeding 2 1 2 See fig 24 Wall Cut out Opening A minimum 10 X 10 250 mm x 250 mm square hole is required for proper pipe clearances through a combustible wall DO NOT FILL AIR S...

Page 15: ...a height 15 ft above the meter regulator assembly I Clearance to service regulator vent outlet 3 ft 91 cm J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any...

Page 16: ...change back for use with natural gas WARNING THE CONVERSION KIT IS TO BE INSTALLED BY AN AUTHORIZED J TUL SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTION AND ALL CODES AND REQUIRE...

Page 17: ...om its brass elbow housing and replace with the appropriate orifice supplied in the kit 10 Replace the Burner Plate Engage the burner tube with the Air Shutter assembly Be sure the burner is level and...

Page 18: ...leaks using a soapy water solution Never use an open flame to check for leaks Leak test 1 Mix a 50 50 solution of water and dish soap 2 Light appliance see lighting instructions on the inside back co...

Page 19: ...2000 feet Check with your gas supplier before performing derate adjustment to the burner If the gas supplier does not derate fuels install High Altitude Adjustment Kit 157675 for Propane and Kit 15767...

Page 20: ...ermostat 750003 Use only a 750 millivolt DC two wire circuit wall thermostat with this appliance The thermostat should be placed in the same room as the heater typically 5 feet off the floor Avoid dra...

Page 21: ...uld be spread sparsely over the burner plate and around the logs Use a pencil to position the stones so as not to block the burner plate porting TO INSURE PROPER BURNER FUNCTION DO NOT OBSTRUCT THE PI...

Page 22: ...lot flame should be steady not lifting or floating The flame should be blue in color around the pilot hood with traces of yellow toward the outer edges The pilot flame should engulf the top 1 8 of the...

Page 23: ...used by incomplete combustion in the flames and lack of combustion air entering the air shutter opening To adjust the air shutter 1 Reach under the stove and loosen the wingnut See fig 45 Slide the wi...

Page 24: ...HE GLASS PANEL REMOVED CRACKED OR BROKEN REPLACEMENT OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON USE ONLY REPLACEMENT GLASS PROVIDED BY YOUR AUTHORIZED J TUL DEALER NEVER SUB...

Page 25: ...de of the rear shroud See fig 48 1 Set the Burner switch to OFF Open the main gas supply line to the stove 2 Connect the AC DC Power Adaptor to the terminal on the back of the DFC board bracket See fi...

Page 26: ...ent should be vacuumed annually to remove any dust and debris Use a soft brush attachment and handle the logs carefully as they are fragile Vacuum more frequently if there are pets in the home The pil...

Page 27: ...rness 3 Control Box 4 Snapstat Bracket 5 Rheostat Knob 6 Snapstat 7 M6 Flange Nuts 2 8 M6 x 12 Hex Bolts 2 9 8 x 1 2 Sheet metal screw 4 Tools Required 1 4 socket driver 10 mm socket driver or wrench...

Page 28: ...ally adjusted with the rheostat knob If the burner turns off the blower will be shut off automatically as the stove cools down If automatic blower circulation is not desired place the blower control s...

Page 29: ...ntact your local officials about installation restrictions and requirements in your area THIS APPLIANCE MAY BE INSTALLED AS AN OEM INSTALLATION IN A MANUFACTURED MOBILE HOME AND MUST BE INSTALLED IN A...

Page 30: ...6 Left Door n a n a 7 Right Door n a n a Front Assembly 15592392 156384 includes Front Doors and Hinge Pins 13 Safety Barrier 157688 n a 8 Hinge Pin 4 125960 9 Fender Washer M6 4 120004 10 Bolt M6 x 2...

Page 31: ...Pole 77 Series 13 22093192 Control Door GF 200 DV IPI 14 221185 Orifice 1 20 mm 225441 Orifice 2 1mm 15 222280 Gasket Drop in Orifice Holder 16 222292 Elbow 90 deg Brass 3 8 NTP x 3 8 dia flare Figur...

Page 32: ...Wing Nut M6 Zinc 10 225092 Air Deflector Burner Skirt 11 225439 Pilot Shield High Wind Optional Kit 157685 12 225438 Pilot Shield 13 224785 Pilot NG LP Dual Fuel Convertible Flame Hood 14 118218 Screw...

Page 33: ...157685 No Part No Description 1 22136592 Glass Frame II 2 129124 Gasket Tadpole 25 dia x 1 25 6 ft 3 220576 Glass Panel Ceramic 4 220042 Replacement Glass Clips 5 155599 Replacement Glass Kit GF 200 D...

Page 34: ...ined in this owner s manual or local and or national fire and building regulations 3 Damage due to service performed by an installer service agency or gas supplier unless otherwise agreed to in writin...

Page 35: ...replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING 1 Set the thermostat to the lowest setting 2 Turn off...

Page 36: ...installation it is important that these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specifi cation color...

Reviews: