Operation
Familiarize yourself with the controls of the GF 200 DV
IPI and be sure that anyone else using the appliance is
also familiar with the controls and operation procedures.
Always follow the Lighting Instructions on the inside back
cover of this manual and also located on the inside of the
Controls Access Door.
This appliance is equipped with an ignition device
that lights the pilot automatically.
Do not try to light the
pilot by hand.
Locate the Burner Control switches at the top left side
of the rear shroud. See fig. 48.
1. Set the Burner switch to
OFF
. Open the main gas
supply line to the stove.
2. Connect the AC/DC Power Adaptor to the terminal
on the back of the DFC board bracket. See fig. 48a.
Connect the adaptor plug to 110 VAC house current.
3. If a wall thermostat is used, set it to the lowest
temperature.
4. Set the Pilot Mode:
•
CPI
for continuous pilot operation
•
IPI
for intermittent operation.
5. Set the Burner Switch to
ON
. The pilot will light.
ON / OFF
- use for manual control of the burner.
STAT
- use with an optional wall thermostat.
6. Flame intensity can be adjusted manually by turning
the Valve Regulator knob shown in Fig. 48a.
Figure 48.
Burner controls location, viewed from above stove.
Figure 48a. Valve and Blower Controls.