
28
139587_05 GF 200 DV IPI October 2015
Figure 52. 155631 Blower Kit Components used for GF 200 DV IPI Lillehammer.
Blower Operation
The variable-speed blower will enhance heat circulation
around the firebox and out into the room. The blower is
controlled by a heat activated switch (snapstat) that will
function only when the control switch is in the AUTO
setting. After the fire has been burning for a time, the
snapstat will react to the heat and activate the blower.
Fan speed may be manually adjusted with the rheostat
knob. If the burner turns off, the blower will be shut off
automatically as the stove cools down.
If automatic blower circulation is not desired, place
the blower control switch in the MANUAL position. That
will override the snapstat, allowing the blower to run
continuously.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IM-
PROPER AND DANGEROUS OPERATION.
VERIFY OPERATION AFTER SERVICING.
ATTENTION:
AU MOMENT DE L’ENTRENTIEN DES COMMANDES,
ETIQUIETEZ TOUS LE FILS AVANT LE DEBRANCHEMENT.
ES ERREURS DE CEBLAGE PEUVENT ENTRA TUN FONC-
TIONNEMENT INADEQUAT ET DANGEREUX.
Figure 53. GF 200 DV IPI Blower Wiring Diagram.