Remove M6 nut from the Primary Baffle support stud.
Exhaust Baffle / Air Deflector Use
Air flow throughout the burner and firebox is critical
to efficient combustion as well as promotion of a
vibrant flame picture. The GF 200 IPI is supplied with
a 2-piece baffle assembly and two air deflector plates
that are intended to provide optimal performance with
either natural gas or propane in a variety of venting
configurations. Use the chart below to set up the firebox
appropriately for your particular installation. See also figs.
10-12.
Figure 11.
Remove the Primary Baffle from Secondary Baffle.
Secondary Baffle
Primary Baffle
Secondary Baffle Use - Fig. 11
Fuel Termination Vent Installed Removed
NG Horizontal
4/6
X
NG Vertical
4/6
X
LP Horizontal
4/6
X
LP Vertical
4/6
X
NG Horizontal
5/8
X
LP Horizontal
5/8
X
Skirt Cover Plate Use - Fig. 12
Fuel Termination Vent Installed
NG Horizontal 5/8
X
NG Vertical
4/6
X
LP Horizontal 5/8
X
LP Vertical 4/6
X
Remove and
Install Air
Deflector
Figure 12.
Vertically Terminated 4/6 Vent:
Remove Burner Skirt Cover Plate and install
the Air Deflector to the underside of the
Burner Skirt.
Sklrt Cover Plate
Burner Skirt
Air Deflector
Skirt & Deflector
Assembly
Primary Baffle