30
07.7
PREPARATION OF HYDRAULIC CONNECTIONS
a) Standard configuration
The representation of the components is approximate, but they can change in terms of shape.
NOTE
In case of fireplace installation with the
standard closed vessel configuration, it is necessary to
supply the components of the COMPLETE HYDRAULIC
KIT respecting its positioning and assembly method.
NOTE
The fireplace is supplied with a built-in safety cooling exchanger. The two hydraulic kits are available on request (optional) depending on the
type of installation chosen: basic kit (only safety valves - see point b) or closed tank hydraulic kit for heating (see - see point c). However,
open vessel installation is possible.
1. Cooling coil cooling water inlet with heat discharge valve
assembly (if not used for open vessel installation it is not
to be connected) (3/4” M)
2. Hot water safety heat discharge (if not used for open
vessel installation it is not to be connected) (3/4” M)
3. Heat discharge valve safety temperature probe well (If
not used for open vessel installation, it must be closed)
(1/2” F)
4. Water inlet for system loading (for closed vessel
installation) or open vessel connection (1/2” F)
5. Temperature probe well (1/2” F)
6.
System flow (1” M)
7. Safety valve connection (for closed vessel installation)
or if not used, it must be closed * (1/2” F)
8. System return (1” M)
* in case of open vessel installation, a pressure safety valve can also be connected to inlet 7.
NOTE
1
2 3
4
5 6 7
8