INSTALLATION CONFIGURATIONS
Install the fireplace as follows:
Images shown are for illustration purposes only.
a) Configuration with fireplace combustion air inlet communicating with the outside.
The fireplace can function by taking the comburent air from the outside, connecting it with the extensible aluminium pipe (Ø120 mm and
maximum length 100 cm) with the outside (1).
In this configuration, the fireplace comburent air inlet connection with the outside environment is mandatory.
Make an opening (minimum 600 cm
2
) in the upper part of the cladding (2) to allow the heat to escape/heat recovery that forms inside the
cladding and an opening (minimum 600 cm
2
) in the lower part of the cladding (3) for the convective circulation of the cladding air.
The coating top and lower parts openings are mandatory.
It is mandatory to carry out an inspection opening on the cladding (4) for access to the part of the hydraulic connections and the
inspection of the flue gas pass.
1
2
3
4
25