1
Strong
Weak
Both 50Hz and 60Hz
MODEL
:
J
UMHX1562
N
32 dB(A)
28 dB(A)
:
SOUND LEVEL
34 dB(A)
STRONG
4000
63
125 250
8000
2000
1000
500
Frequency at center of sound pressure band (Hz)
Overall
4000
63
125 250
8000
2000
1000
500
Frequency at center of sound pressure band (Hz)
Overall
60
50
40
30
20
10
Sound pressure level (dB)
(0dB = 0.0002μbar)
Approximate
minimum
audible limit for
continuous noise
MODEL
:
:
:
J
UMHX1262
N
SOUND LEVEL
WEAK
CONDITION
STRONG
4.9 ft. directly below unit
MODEL
:
:
:
J
UMHX1862
N
SOUND LEVEL
35 dB(A)
WEAK
31 dB(A)
CONDITION
STRONG
4.9 ft. directly below unit
:
CONDITION
4.9 ft. directly below unit
60
50
40
30
20
10
Sound pressure level (dB)
(0dB = 0.0002μbar)
Approximate
minimum
audible limit for
continuous noise
WEAK
30 dB(A)
Sound pressure level (dB)
(0dB = 0.0002μbar)
60
50
40
30
20
10
Frequency at center of sound pressure band (Hz)
4000
63
125 250
8000
2000
1000
500
Overall
Approximate
minimum
audible limit for
continuous noise
MODEL
:
J
UMHX0962
N
28 dB(A)
25 dB(A)
:
SOUND LEVEL
30 dB(A)
STRONG
4000
63
125 250
8000
2000
1000
500
Frequency at center of sound pressure band (Hz)
Overall
60
50
40
30
20
10
Sound pressure level (dB)
(0dB = 0.0002μbar)
Approximate
minimum
audible limit for
continuous noise
MODEL
:
:
:
J
UMHX0762
N
SOUND LEVEL
WEAK
CONDITION
STRONG
4.9 ft. directly below unit
:
CONDITION
4.9 ft. directly below unit
WEAK
27 dB(A)
Sound pressure level (dB)
(0dB = 0.0002μbar)
60
50
40
30
20
10
Frequency at center of sound pressure band (Hz)
4000
63
125 250
8000
2000
1000
500
Overall
Approximate
minimum
audible limit for
continuous noise
4.9 ft.
Air discharge
(Concealed-Duct Type)
Air intake
Unit
4.9 ft. directly below unit
Auxiliary Duct
of 6.6 ft. length
Auxiliary Duct
of 3.3 ft. length
REMARKS:
1. Value obtained in the actual place where the unit is
installed may be slightly higher than the values shown
in this graph because of the conditions of operation,
the structure of the building, the backgroundnoise and
other factors.
2. The test results were obtained from an anechoic room.
3. The layout of the testing condition is shown at right.
To evaluate the noise level, the maximum value of the measured sound pressure level is used. Read the value at
each frequency level (on horizontal axis, center of the sound pressure band) from 63 Hz to 8000 Hz, and select the
corresponding maximum value indicated on the vertical axis.
NC-20
NC-30
NC-40
NC-50
NC-20
NC-30
NC-40
NC-50
NC-20
NC-30
NC-40
NC-50
NC-20
NC-30
NC-40
NC-50
NC-20
NC-30
NC-40
NC-50
NOTE
TD831149-00̲3WAY.indb 82
2010/01/26 15:11:16
FORM 121.00-EG1
ISSUE DATE: 5/31/2012
JOHNSON CONTROLS
92
FORM 121.00-EG1
ISSUE DATE: 5/31/2012
JOHNSON CONTROLS
92
Slim Concealed Duct, Standard and Slim (JU, JUM Type)
Summary of Contents for JA Series
Page 181: ...Schematic Diagram JDHX3652N FORM 121 00 EG1 ISSUE DATE 5 31 2012 181 JOHNSON CONTROLS ...
Page 183: ...Schematic Diagram JDHX4852N FORM 121 00 EG1 ISSUE DATE 5 31 2012 183 JOHNSON CONTROLS ...
Page 189: ...Schematic Diagram JKHX1862N FORM 121 00 EG1 ISSUE DATE 5 31 2012 189 JOHNSON CONTROLS ...
Page 191: ...Schematic Diagram JKHX2452N FORM 121 00 EG1 ISSUE DATE 5 31 2012 191 JOHNSON CONTROLS ...