Installation Precautions
To reduce the risk of serious injury or death, the following installation
precautions must be followed.
Ɣ
When installing the unit into…
ƕ $ZDOO0DNHVXUHWKHZDOOLVVWURQJHQRXJKWRKROGWKHXQLW¶VZHLJKW,WPD\EHQHFHVVDU\WR
construct a strong wood or metal frame to provide added support.
ƕ
A room: Properly insulate any refrigerant tubing run inside a room to prevent “sweating” that can
FDXVHGULSSLQJDQGZDWHUGDPDJHWRZDOODQGÀRRUV
ƕ
Damp or uneven areas: Use a raised concrete pad or concrete blocks to provide a solid, level
foundation for the unit to prevent water damage and abnormal vibration.
ƕ $QDUHDZLWKKLJKZLQGV6HFXUHO\DQFKRUWKHRXWGRRUXQLWGRZQZLWKEROWVDQGDPHWDOIUDPH
3URYLGHDVXLWDEOHDLUEDIÀH
ƕ
A snowy area: Install the outdoor unit on a raised platform that is higher than drifting snow.
Provide snow vents.
Ɣ
If the remote sensors are not used with this controller, then do not install this controller…
ƕ
in a room where there is no thermostat.
ƕ
where the unit is exposed to direct sunshine or direct light.
ƕ
where the unit will be in close proximity to a heat source.
ƕ
where hot/cold air from the outdoors, or a draft from elsewhere (such as air vents, diffusers or
grilles) can affect air circulation.
ƕ
in areas with poor air circulation and ventilation.
Ɣ
'RQRWLQVWDOOWKHXQLWLQWKHIROORZLQJSODFHV'RLQJVRFDQUHVXOWLQDQH[SORVLRQ¿UHGHIRUPDWLRQ
corrosion, or product failure.
ƕ ([SORVLYHRUÀDPPDEOHDWPRVSKHUH
ƕ :KHUH¿UHRLOVWHDPRUSRZGHUFDQGLUHFWO\HQWHUWKHXQLWVXFKDVLQFORVHSUR[LPLW\RUGLUHFWO\
above a kitchen stove.
ƕ
Where oil (including machinery oil) may be present.
ƕ :KHUHFRUURVLYHJDVHVVXFKDVFKORULQHEURPLQHRUVXO¿GHFDQDFFXPXODWHVXFKDVQHDUDKRW
tub or hot spring.
ƕ :KHUHGHQVHVDOWODGHQDLUÀRZLVKHDY\VXFKDVLQFRDVWDOUHJLRQV
ƕ
Where the air quality is of high acidity.
ƕ
Where harmful gases can be generated from decomposition.
Ɣ
Do not position the drain pipe for the indoor unit near any sanitary sewers where corrosive gases
may be present. If you do, toxic gases can seep into breathable air spaces and can cause respiratory
LQMXULHV,IWKHGUDLQSLSHLVLQVWDOOHGLQFRUUHFWO\ZDWHUOHDNDJHDQGGDPDJHWRWKHFHLOLQJÀRRU
furniture, or other possessions may result. If condensate piping becomes clogged, moisture can back
up and can drip from the indoor unit. Do not install the indoor unit where such dripping can cause
moisture damage or uneven locations: Use a raised concrete pad or concrete blocks to provide a
solid, level foundation for the unit to prevent water damage and abnormal vibration.
Ɣ
%HIRUHSHUIRUPLQJDQ\EUD]LQJZRUNEHVXUHWKDWWKHUHDUHQRÀDPPDEOHPDWHULDOVRURSHQÀDPHV
nearby.
Ɣ
3HUIRUPDWHVWUXQWRHQVXUHQRUPDORSHUDWLRQ6DIHW\JXDUGVVKLHOGVEDUULHUVFRYHUVDQGSURWHFWLYH
GHYLFHVPXVWEHLQSODFHZKLOHWKHFRPSUHVVRUXQLWLVRSHUDWLQJ'XULQJWKHWHVWUXQNHHS¿QJHUVDQG
clothing away from any moving parts.
Ɣ
&OHDQXSWKHVLWHZKHQ¿QLVKHGUHPHPEHULQJWRFKHFNWKDWQRPHWDOVFUDSVRUELWVRIZLULQJKDYH
been left inside the unit being installed.
Ɣ
During transportation, do not allow the backrest of the forklift make contact with the unit, otherwise,
it may cause damage to the heat exchanger and also may cause injury when stopped or started
suddenly.
Ɣ
5HPRYHJDVLQVLGHWKHFORVLQJSLSHZKHQWKHEUD]LQJZRUNLVSHUIRUPHG,IWKHEUD]LQJ¿OOHUPHWDOLV
melted with remaining gas inside, the pipes will be blown off and it may cause injury.
Ɣ
Be sure to use nitrogen gas for an airtight test. If other gases such as oxygen gas, acetylene gas or
ÀXRURFDUERQJDVDUHDFFLGHQWDOO\XVHGLWPD\FDXVHH[SORVLRQRUJDVLQWR[LFDWLRQ
$IWHULQVWDOODWLRQZRUNIRUWKHV\VWHPKDVEHHQFRPSOHWHGH[SODLQWKH³6DIHW\3UHFDXWLRQV´WKHSURSHUXVH
and maintenance of the unit to the customer according to the information in all manuals that came with the
system. All manuals and warranty information must be given to the user or left near the Indoor Unit.
Summary of Contents for (H
Page 2: ......
Page 10: ...viii TC 16006 ...
Page 22: ......
Page 32: ...OUTDOOR UNITS 2 10 TC 16006 2XWGRRU 8QLWV 0RGHO 9 3 DQG 9 3 LQFK PP ...
Page 45: ...OUTDOOR UNITS TC 16006 2 23 RQWURO 6 VWHP 5HIULJHUDQW FOH 0RGHO 9 3 9 3 9 3 DQG 9 3 LQFK PP ...
Page 64: ...OUTDOOR UNITS 2 42 TC 16006 2 460V 60Hz MODEL H Y VAHP072B41CW and H Y VAHP096B41CW ...
Page 90: ......
Page 124: ... 2016 Johnson Controls Inc TC 16006 Code No LIT 12012299 Issued August 2016 ...