Johnson Controls CR-NDT150-1 Manual Download Page 2

G

eneral features

Controller

Based on the field proven MR family of
controllers, it integrates specific features
required in cold rooms.

Positive temperature applications:

MR12DR230-1C

 

Pump down management (selectable)

 Fan 

option

Negative temperature applications:

MR15DR230-2C

 

Pump down management (selectable)

 Fan 

management

For additional information please refer to MR
documentation

Sensor

The CR series uses Johnson Controls A99
temperature sensor. Its accuracy, ± 0.5 K over a
range from -20ºC to 75ºC, and its gas tight
packaging makes it the best sensor for
refrigeration applications.

For details please refer to A99 documentation.

Circuit Breaker for motor

(Three phase models only)

Selected for its high protection against short
circuit, it features phase disconnection, thermal
protection and manual On/Off. The adjusted
protection value is independent of temperature
condition inside your cabinet.

For details on the short circuit protection, see
information page 13.

Circuit Breaker for controller, defrost
and fans

Specifically selected for virtually all applications it
features a high protection and an appropriate
magneto-thermal characteristic in function of the
application.

Positive temperature applications:

Mainly inductive loads: Curve D

Negative temperature applications:

Mainly resistive loads: Curve C

Negative temperature applications three
phase defrost only:

Mainly inductive loads: Curve D
Defrost Line: Curve C

For details, see information page 13.

Contactor

A VDR protection across the coil extends the life
of the controller relays. The contactor, being four
(4) poles, allows you to customise the cabinet to
your application. This additional contact could be
used to drive a condensing fan (up to 3 Amps) or
for signalling its operation.

Selected for use in AC-3 category: three-phase
motor with cage with a nominal speed of 1500
rpm.

Cabinet

Thanks to a specifically designed MR, there is
sufficient space in the cabinet in order to extend
your application.
Wiring is easily accessible.
The high protection level (IP65) allows you to
install this cabinet in harsh environment such as
outdoors. The polycarbonate material has a high
shock resistance, which could be necessary
during handling or at installation.

The class 2 

 insulation gives you the safety

required by all agencies.

2

CR1

Catalogue Section 9

© 2000 Johnson Controls, Inc.

Summary of Contents for CR-NDT150-1

Page 1: ...modules back models Features and Benefits Power rating from 0 37 to 1 5 kW in single phase 1 5 to 7 5 kW in three phases Cover most of standard applications Standard DIN rail components Easy maintena...

Page 2: ...it features a high protection and an appropriate magneto thermal characteristic in function of the application Positive temperature applications Mainly inductive loads Curve D Negative temperature ap...

Page 3: ...al rules These controllers are designed for use as an operating control When an operating control failure would result in personal injury or loss of property it is the responsibility of the installer...

Page 4: ...following functions Shut OFF If the contact is open for a preset time all outputs are de energised and an alarm message is displayed External alarm Display shows AL the Alarm output is switched ON al...

Page 5: ...t pum p down A99 1L1 3L2 5L3 2T1 4T2 6T3 I I I A1 1L1 3L2 5L3 2T1 4T2 6T3 A2 Compressor 3 400 Volts MR12DR230 B1 A D A N 13 7 4 N N N N 4 1 3N 2 4N Alarm 230V 0 5 A 8T4 7L4 21 22 3 Fan Compressor Comp...

Page 6: ...temperature has dropped below a user settable temperature Condensing fan or door frame heater On the 3 phase models two terminals are available to field connect a condensing fan or a door frame heate...

Page 7: ...p down A99 1L1 3L2 5L3 2T1 4T2 6T3 I I I A1 1L1 3L2 5L3 2T1 4T2 6T3 A2 Compressor 3 400 Volts MR15DR230 10 11 B1 A D A B2 A N 13 7 4 N N N N 4 1 3N 2 4N Alarm 230V 0 5 A 8T4 7L4 21 22 N 20 3 Compress...

Page 8: ...g diagram Valve Pum p down Defrost 230 V 3 reaker 1P N Circuit B Circuit 400 V Breaker 3 Contactor Fan 230 Volts A99 Contact pump down A99 1L1 3L2 5L3 2T1 4T2 6T3 I I I A1 1L1 3L2 5L3 2T1 4T2 6T3 A2 C...

Page 9: ...1L1 3L2 5L3 2T1 4T2 6T3 I I I A1 1L1 3L2 5L3 2T1 4T2 6T3 A2 Compressor 3 400 Volts MR15DR230 10 11 B1 A D A B2 A N 13 7 4 N N N N 4 Alarm 230V 0 5 A 8T4 7L4 21 22 Pressure switch HP BP 3 1L1 3L2 5L3...

Page 10: ...room temperature exceeds 4 6 10 C for a time greater than parameter At the alarm is activated when temperature drops below 4 6 2 8 C the alarm is reset At Alarm time delay Delay between the detection...

Page 11: ...digital input opening and the enabling of the function selected through parameter iF FF Fan operating function 0 fan runs in parallel to the compressor 1 fan is always ON Note in both cases the fan is...

Page 12: ...Max defrost duration 0 to 99 min 40 dC Dripping time 0 to 99 min 5 dU First defrost after power on OFF 0 to 99 min OF dP Display during defrost 0 Last value before defrost 1 Set point 0 dr Delay disp...

Page 13: ...er s documentation in this case ABB Characteristic of the circuit breaker for motor three phase models only Item Control range Interruption capacity against short circuit 380 400 Vac Ics kA CR PT150 1...

Page 14: ...que Circuit breakers S254 Cxx series Circuit breaker for 3ph defrost see relative amperage value in the wiring diagram ABB Elettrocondoture S271 Na xxx 1ph N circuit breaker for digital controller see...

Page 15: ...Notes CR1 15 2010 Johnson Controls Inc Catalogue Section 9...

Page 16: ...mps 230 V ac Dimensions H x W x D 12 Modules 18 Modules 24 Modules 36 Modules 275 x 220 x 140 380 x 220 x 140 275 x 370 x 140 380 x 370 x 140 Directives EN 60439 1 Tested Type Appliance TTA The perfor...

Page 17: ...isfonctionnement d un appareil de r gulation peut entrainer des blessures au personnel ou une perte d exploitation la responsabilit en incombe l installateur Celui ci doit pr voir des quipements ou de...

Page 18: ...eme die bei Ausfall oder St rung der Steuerung eine Warn oder Schutzfunktion haben in die Steuerung integriert und als Teil des Regelsystems gewartet werden Nota Estos controles est n dise ados para s...

Page 19: ...et installat rens ansvar at installere udstyr eller systemer der kan beskytte mod eller advare om styringsfejl Huomaa N m s timet on tarkoitettu k ytett v ksi vain k ytt s timin Asentaja on vastuussa...

Page 20: ...atorsch tz Motorschutzschalter Verdampfer Ventilatorschutzschalter Abtauschutzschalter 4 polig Reglerschutzschalter Hauptsch tz NEDERLANDS Regelaar Compressor relais Ontdooi relais Verdamper Ventilato...

Reviews: