NT-2000 REF Manual
Installation
7-18
7.4.5. Proprietary
Sentences
The following commands (IEC 61162–1proprietary format sentence) are supported to
externally switch the second receiver frequency:
$PJMCR
,
0
,
1
*
hh <
C
R> <
L
F>
①
②
③
①
Receiver index:
0 = Second receiver
1 to 9 = Reserved
②
Receive frequency index:
1 = 490 kHz
2 = 4209.5 kHz
③
Checksum
See the examples below.
Examples:
・
Switching to 490 kHz:
$PJMCR
,
0
,
1
*
47<
C
R><
L
F>
・
Switching to 4209.5 kHz:
$PJMCR
,
0
,
3
*
45<
C
R><
L
F>