SECTION 6 - LSS SETUP/CALIBRATION/SERVICE
6-4
31215079
Pressing the ENTER key will confirm that the platform is
empty (except for factory-installed options outside the
Rated Load). The LSS Module will calculate the total of
all load cell readings and ensure that the total is greater
than minimum calibration value, but less than maxi-
mum calibration value. If successful, the Analyzer will
show the following:
CALIBRATE:
COMPLETE
If the empty platform weight is less than minimum cali-
bration value, the calibration attempt will be unsuccess-
ful and the Analyzer will show the following:
CALIBRATE:
< MIN CAL
If the empty platform weight is greater than maximum
calibration value, the calibration attempt will be unsuc-
cessful and the Analyzer will show the following:
CALIBRATE:
> MAX CAL
Table 6-5. Calibration Values
MODELS
330RT
430LRT
Minimum Calibration Value
225 KG
(496 LB)
225 KG
(496 LB)
Maximum Calibration Value
1150KG
(2535.3 LB)
1000KG
(2204.6 LB)