58
OM131
Chapter 4
P1939-OM-131 R11
4.3.1.3 Check actuation of SLS system backpack
1.
Remove the outer door, scrubber door and CO
2
scrubber canister.
2.
Actuate the SLS System by pulling the actuation handle.
N
OTE
The actuation effort should not exceed 10kg if the equipment is well maintained.
3.
Check that the spool valve has actuated and that there is a bleed of gas into the SLS System,
by listening for a flow.
4.3.1.4 Check gas flow from single stage regulator
N
OTE
This should be done with the supply hose connected to the Helmet to ensure that the single stage
regulator inlet filter and the helmet side-block connector filter are not contaminated and restricting
the flow.
1.
Connect the SLS System Backpack single stage regulator hose to the SLS System Helmet
sideblock and connect an AIR supply to the helmet.
2.
Remove the blanking plug from the first stage regulator test port and insert the test gauge
(Divex Part No. DM32540) from the Tool and Test Kit.
3.
Remove the scrubber door and CO
2
scrubber canister.
4.
Insert the flowmeter connector (Divex Part No. DM32580) from the Tool and Test Kit into the
main supply penetrator.
5.
Connect a breathing quality AIR supply directly to the umbilical hose on the SLS System and
set a supply pressure equal to the expected helmet supply pressure from the tables in chapter
3 of the SLS Helmet Manual OM112.
6.
Blank the top port on the test flowmeter (Divex Part No. DM32580).
7.
Allow the test hose to pressurise until the pressure stabilises.
8.
Check the pressure gauge, which should read 138 mbar (2 psi).
9.
If not adjust regulator by slackening locknut (Fig 4.8, Item 17, page 74) and using the Allen
key provided, move the regulator adjustment screw, until 138 mbar (2 psi) is reached and
tighten the locknut.
6
Counterlung Assembly
CA2607
7
Weight Pocket
D308
8
Handle Retaining Band
D302
9
Rescue Lifting Point
-
10
Cable Wiper Sleeve
D328
11
Bush
D322
Item
Description
Part No
Summary of Contents for Divex SLS Mk IV
Page 2: ...Intentionally Blank...
Page 4: ...ii OM131 Approval Sheet P1939 OM 131 R11 Intentionally Blank...
Page 6: ...iv OM131 Preface P1939 OM 131 R11 Intentionally Blank...
Page 8: ...vi OM131 List of Abbreviations P1939 OM 131 R11 Intentionally Blank...
Page 10: ...viii OM131 Warnings P1939 OM 131 R11 Intentionally Blank...
Page 12: ...x OM131 Table of Contents P1939 OM 131 R11 Intentionally Blank...
Page 15: ...OM131 3 P1939 OM 131 R11 Chapter 1 Fig 1 1 SLS System Mk IV...
Page 16: ...4 OM131 Chapter 1 P1939 OM 131 R11 Fig 1 2 SLS system layout...
Page 32: ...20 OM131 Chapter 2 P1939 OM 131 R11 Fig 2 4 Two stage regulator Fig 2 5 Spool valve...
Page 42: ...30 OM131 Chapter 2 P1939 OM 131 R11 Intentionally Blank...
Page 53: ...OM131 41 P1939 OM 131 R11 Chapter 3 Fig 3 3 Hose Lanyards...
Page 54: ...42 OM131 Chapter 3 P1939 OM 131 R11 Fig 3 4 SLS System Mk IV Rear View...
Page 55: ...OM131 43 P1939 OM 131 R11 Chapter 3 Fig 3 5 SLS System Mk IV Front View...
Page 64: ...52 OM131 Chapter 3 P1939 OM 131 R11 Intentionally Blank...
Page 82: ...70 OM131 Chapter 4 P1939 OM 131 R11 Fig 4 7 Annual Maintenance Two Stage Regulator...
Page 86: ...74 OM131 Chapter 4 P1939 OM 131 R11 Fig 4 8 Annual Maintenance Single Stage Regulator...
Page 109: ...OM131 97 P1939 OM 131 R11 Chapter 5 Fig 5 2 Backpack Assembly Drawing P1939229S1...
Page 111: ...OM131 99 P1939 OM 131 R11 Chapter 5 Fig 5 4 Scrubber Housing Assembly Drawing P1939131S1...
Page 118: ...106 OM131 Chapter 5 P1939 OM 131 R11 Fig 5 9 SLS System Mk IV Gas Schematic Drawing P193940S1...
Page 123: ...OM131 111 P1939 OM 131 R11 Chapter 5 Fig 5 14 SLS System Mk IV Bottle Assembly...