JetMove 208-480
7.6 External Ballast Resistor and DC Link Connection
Jetter AG
67
Parameters of external ballast resistor in this configuration:
These are the same values as with the internal resistor.
As an alternative, the following parameters can apply to a resistor:
This configuration causes the energy dissipation to be twice as high as it would be if
configured with an internal resistor only.
With both resistors, the internal overload control is working as well as using the
internal ballast resistor only.
Coupling DC Link Circuits of Two or Three
JetMove 208-480
Another way uf utilizing the braking energy of the motor is to couple the DC links of
several JetMove 208-480. In most cases, not all axes of a machine have to brake at
the same time. So, other axes can use the energy coming back for acceleration.
The coupling reduces the heat inside the amplifier emitted by the ballast resistor and
provides a higher dynamic if not all axes accelerate at the same time.
Value of the resistor:
88
Continuous power:
140 W or greater
Maximum capacity:
3 kW for 0.6 s
Type:
Low inductivity
Ω
Value of the resistor:
44
Continuous power:
280 W or greater
Maximum capacity:
6 kW for 0.6 s
Type:
Low inductivity
Ω
Summary of Contents for JM-208-480-OEM
Page 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Page 22: ...1 Safety Instructions 22 Jetter AG...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...9 Diagnostics 82 Jetter AG...
Page 86: ...10 Connection Diagrams 86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 208 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...