13.5.3 Application 2
Fig.: 27: Application 2
The safety device(s) transmit(s) a +24 V signal for activating the digital servo
amplifier to the input Enable1 and Enable2 individually. At calling up the safety
function, both contacts open and thus block the enabling signal. In case of an error,
it is sufficient that at least one of those two contacts opens, in order to switch off the
motor safely (dual-channel switch-off). Deactivating the inputs leads to immediate
switching off the motor (Stop Category 0). By means of the wiring technology, a
short, both between the contacts of the emergency stop device, and between the two
lines, can be precluded.
As this application is not self-testing, proper function must be tested regularly. These
tests are to prove freedom from faults of the entire system.
Following this example, "Safe Standstill" (according to EN 954-1 Category 2) with
Stop Category 0 (according to EN 60204) can be set up, if all safety devices involved
also meet the requirements of Category 2.
E2
COM
E1
JetMove (D)2xx
Contact for
the Safety
Device
Contact for
the Safety
Device
Summary of Contents for JM-208-480-OEM
Page 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Page 22: ...1 Safety Instructions 22 Jetter AG...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...9 Diagnostics 82 Jetter AG...
Page 86: ...10 Connection Diagrams 86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 208 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...