JetMove 208-480
14.1 Description
Jetter AG
107
14
Counting Input (Option)
14.1
Description
For the JetMove 208-480, an optional integrated counter card can be ordered (article
designation of the device: JM-208-480...-CNT). It supplies a counting input equipped
with the following interface:
• EnDat 2.2 by Heidenhain
• Synchronous Serial Interface (SSI)
• Incremental counter
The received or counted value of an actual position can be read via a JetMove
register by the controller program or processed by the firmware of the JetMove in the
controllers.
Yet, the actual position of an SSI encoder cannot be used for position control. It only
indicates the position of the leading axis.
14.2
EnDat 2.2
14.2.1 Technical Data
Technical Data of the Input EnDat 2.2
Encoder types
Single-, multiturn, or linear absolute encoders
Scanning
62.5 µs
Baud rate
8 MHz
Maximum cable length
100 m
Type of signal
5 V differential signal
Input impedance
22 k
Bus termination
120
integrated resistance
Electrical isolation
None
Ω
Ω
Summary of Contents for JM-208-480-OEM
Page 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Page 22: ...1 Safety Instructions 22 Jetter AG...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...9 Diagnostics 82 Jetter AG...
Page 86: ...10 Connection Diagrams 86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 208 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...