JetMove 208-480
7.5 Sin-Cos Encoder Connection
Jetter AG
63
Important!
To be considered before connecting sin-cos encoders
If a sin-cos encoder is to be used, commutation finding
always
has to
be carried out after applying the logic power supply and before giving
the first enable.
If this is not considered, the motor might move uncontrollably.
The counting direction of the position in the JetMove 2xx is reversed in
the following cases:
Case 1: The signal sine+ is exchanged with the signal , and the
signal reference sine is exchanged with the signal reference cosine.
Case 2: The signal sine is exchanged with the signal reference sine.
Case 3: The signal cosine is exchanged with the signal reference
cosine.
Due to conduction loss, a voltage smaller than 5 V might reach the
encoder. If necessary, the encoder supply cords have to have a greater
diameter.
If a motor temperature sensor is not used, the inputs have to be short-
circuited at the adapter, so the JetMove 208-480 will not give an error
message.
Summary of Contents for JM-208-480-OEM
Page 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Page 22: ...1 Safety Instructions 22 Jetter AG...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...9 Diagnostics 82 Jetter AG...
Page 86: ...10 Connection Diagrams 86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 208 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...