Jets™ 25MBA Vacuumarator™ pump
Tel. +47 70 03 91 00
www.jetsgroup.com
Product No. 200025004
Doc. Rev.: 22 (2021-06-08)
12
25
Remove the rotating part of the shaft
seal (21B).
Important: Do not touch ceramic
surfaces on the shaft seal. Residue
will affect operation.
26
Remove the flange
⅁
.
27
Remove the stationary part of the
shaft seal (21A) from the flange
⅁
.
28
Remove the eight nuts (3.1) from
the suction chamber.
29
Remove the cover
℮
from the
suction chamber.
30
Remove the O-ring
ℯ
from the
cover
℮
.
31
Remove the nut (37), the flange (38)
and the O-ring (39).
32
Remove the flap valve from the
suction chamber
ℰ
.
33
Remove the two nuts (36), the plate
(35) and the rubber flap (34) from the
flap valve (33).
34
Remove the four screws (23)
holding the motor flange.
35
Remove the stator (27) and the
spacer sleeve (28).
36
Remove the motor flange (25).
Gentle use of a rubber mallet
may be required. Remove the
sealing ring (22).