Jets™ 25MBA Vacuumarator™ pump
Tel. +47 70 03 91 00
www.jetsgroup.com
Product No. 200025004
Doc. Rev.: 22 (2021-06-08)
11
13
Remove the four screws (M5x12)
securing the stationary knife in place.
14
Remove the stationary knife from
the assembly.
15
Remove the four stay bolts
℺
.
16
Remove the end flange
ℹ
from
the rotor housing
ℽ
.
17
Remove the O-ring
℻
.
18
Remove the rotor housing
ℽ
.
19
Remove the rotor
ℼ
.
20
Remove the O-ring
℻
.
21
Remove the pressure chamber
ℾ
. A
rubber mallet may be required.
22
Remove the key
ℿ
.
23
Remove the O-ring
℻
.
24
Remove the spacer sleeve
⅀
.