Installation & Operation manual of Jetmaster Vent Free Drop In Fireplace
Page 7
Revision 02 @ 04/09
STEP 2
Centrally locate the frame, into the hole provided. It is recommended that clear silicone be used to glue the frame
onto the surface. This will allow for removal of the frame at a later stage, without damaging of the surface or the
frame.
NOTE:
The Infra red sensor for this unit is located at one of the short sides of the burner. This should be located at
the same side as the electronic control board. It is thus important to make sure that the tray is placed with the
control module on the side that would be best suited to have the IR sensor.
THE GAS CONNECTION
STEP 1
The gas supply line must now be connected to the appliance. The following components must be connected as
illustrated below:
•
8mm copper pipe to the valve inlet
•
In line test point to the 8mm copper pipe
•
The 8mm copper pipe which is the gas supply line to the unit.
After connecting the gas supply line, a leakage test must be performed. It is the responsibility of the gas installer to
ensure that a leak testing method, suitable for the specific installation is being used.
NOTE
: Before commissioning, gas leaks can be detected only between the supply point and the inlet to the
appliance. Once the appliance is operational, and additional check must be done for leaks inside the appliance.