TECHNICAL DATA
DIMENSIONS
MODEL
Width
Length
Depth
DROP IN 1020
360mm
1020mm
160mm
GAS SPECIFICATIONS
MODEL
GAS
CONSUMPTION
Max rate
GAS
CONSUMTION
Min rate
injector
Gas supply
pressure
DROP IN 1020 CST
43 MJ/hour
12 kW
0.8 kg/h
28 MJ/hour
8.0 kW
0.6 kg/h
1.7mm
#1
2.8 kPa
DROP IN 1020 HV
43 MJ/hour
12 kW
0.8 kg/h
28 MJ/hour
8.0 kW
0.6 kg/h
1.8mm
#1
2.8 kPa
#1 – The appliance must be installed using an appropriate regulator that can maintain the operating gas
supply pressure during use and that complies with the requirements of SANS 1237.
NOTE:
We suggest that you check the Data Plate on your Gas Burner and verify the Model on the above table, for future
reference.
WARNINGS
•
Do not place articles on or against this appliance
•
Do not use or store flammable materials near this appliance
•
Do not spray aerosols in the vicinity of this appliance while it is in operation
•
These units incorporates a live fuel effect and is designed to burn with luminous flames and as such may
exhibit slight carbon deposits (soot)
Summary of Contents for DROP IN 1020