background image

.  .  .  

AUto...OFF...1sec.....9sec

hold to change

12

0005

000.0

100.0

100.0

13

To change the display clear  method

1.   Press the menu keys.
2.   Press the next key 6 times or until the “Auto 
Reset” icon shows. 
3.   Press the save key to select the Auto Reset 
function.
4.   Press the next key until:
      “AUt0” shows (Auto sense)
      “Off” (manual clear using the clear key)
      “1…….9” (seconds before the display clears 
itself)
5.   Press the save key to store new setting.
Note:
If auto sense is selected the torque meter will 
automatically clear the display when a new 
torque cycle begins. This means that you do not 
have to continually reach up and clear the display 
manually.

Entering the limits (tolerance) settings.

1. From the operation mode press and hold the 
limits on/off key.
If you have set the % function set then the meter 
will prompt you to enter the target tolerance (it will 
automatically calculate the limits).

If you have the high/low function set then the 
meter will first prompt you to enter the low limit 
and then the high limit.

Power saving standby  mode

When the torque meter has not been used for 
approximately 3 minutes it will go into the power 
down or “standby” mode.     The display will show 
“. . .”. 
    Press the clear key to get back to normal 
operation. For the longest life from the batteries 
turn the meter off when not used.

Entering Numbers

When a number needs to be entered or changed  a 
default value (or the last value entered) will be 
shown.

The active digit that can be changed will blink.   

Press the increase key to increase the value of the 
blinking digit.
Press the next key to go to the next digit.
Press the increase key to increase the value of the  
blinking digit.
Repeat for digits 3 and 4.
When the number is correct, press the save key to 
save the new value. 

Zeroing the display

If you press the increase and next keys at the same 
time you will “Zero” the unit.  Make sure that there 
is no load on the transducer when pressing the zero 
keys. The meter will not read torque until 
approximately 2% of the transducer range has been 
reached, therefore you should zero the unit even 
when the display shows zero when changing 
directions. The meter also does an automatic zero 
when the power is turned on.

IMPORTANT!

Always zero the unit when changing direction.  If you plan to use the meter in the 
counterclockwise direction load the transducer three times in the counterclockwise 
direction (to full scale) and then zero the display.  Press the zero keys even if the display 
shows “000.0” This will compensate for small amounts of hysteresis (hysteresis is a natural 
characteristic of steel).

Summary of Contents for TTS-1000

Page 1: ...1 TS 1000 TTS 1000 Torque Tester Operation Manual Rev 2 2008...

Page 2: ...h it from the competition For example there is a first peak mode that allows you to test and calibrate micrometer clicking type torque wrenches However just having this software mode is not enough you...

Page 3: ...nteror computer 10 To erasememory 10 To setfilters 10 To changethe tolerancevalue 11 To makehigh low limits thedefaulttolerance method 11 To changethedisplay clear reset method 12 Enteringthelimitsval...

Page 4: ...nsducer mode allows easy adaptation to third party transducers Software selectable filters Auto convert engineering units Super large 5 8 high digits Memory for up to 1350 torque data External power R...

Page 5: ...n other units Increases value of blinking digit when setting numbers Selects next digit when setting numbers Selects next function when in Menu mode Scrolls through data in memory when recalling memor...

Page 6: ...Belt mount Suggested mounting positions Loosen the 4 locking screws prior to adjusting Reverse bracket and hang on a thin shelf Typical bench mounting Vertical wall Under a shelf Over a ledge 6...

Page 7: ...icrometer torque wrench and disregard further input This mode is used to test and calibrate click type torque wrenches To change the units of measure 1 Press the units key until the arrow points to th...

Page 8: ...value 1 Press the recall key 2 Press the clear key when finished viewing and return to operation Note You can press the save key to save the recalled torque value before pressing the clear key This al...

Page 9: ...w memory values do the following 1 Press menu keys set up icon comes on 2 Press the next key once or until the recall mem icon is on if you miss keep pushing the next key until recall mem shows 3 Pres...

Page 10: ...ave key to select the erase memory function the display will blink giving you a second chance to decide if you really want to erase memory 4 Press the save key again to confirm and erase the memory or...

Page 11: ...rance vs High Low Go No Go Calculation To make high low limits the default tolerance mode 1 Press the menu keys 2 Press the next key 5 times or until tolerance shows 3 Press the save key to select the...

Page 12: ...you do not have to continually reach up and clear the display manually Entering the limits tolerance settings 1 From the operation mode press and hold the limits on off key If you have set the functio...

Page 13: ...time you will Zero the unit Make sure that there is no load on the transducer when pressing the zero keys The meter will not read torque until approximately 2 of the transducer range has been reached...

Page 14: ...s at least 25 greater in range than the expected torque it will apply This may help avoid accidental over torque The torque transducers that are supplied with the torque meter will accept up to 50 ove...

Page 15: ...h and will not tip wen applying torque Bolting the bench to the ground may be necessary on higher range transducers Make sure the cable is pointing down 4 O CLOCK POSITION when mounted on a bench This...

Page 16: ...nough to allow no more than 150 175 lb person to generate the force required to generate the needed torque Using the above arm lengths will be consistent with this philosophy The accuracy of the meter...

Page 17: ...G HANGERS WILL GIVE AN INCORRECT ZERO READING AND MAY THROW OFF ACCURACY 4 AFTER STEP 3 ABOVE PRESS THE ZERO BUTTONS EVEN IF THE DISPLAY SHOWS 000 0 DO NOT PRESS THEM AGAIN UNTIL YOU START A COMPLETE...

Page 18: ...you do not select the custom transducer number the meter will revert to the calibration data on the chip inside the transducer You can tell if the system is using the smart chip inside the transducer...

Page 19: ...l now show CCW FS which is prompting you to apply the Full Scale weights to the arm in the counterclockwise direction Apply the full scale weights in the counterclockwise direction stabilize the weigh...

Page 20: ...e smart data not the custom data when it is turned on Select the custom transducer in this case Do this by pressing the transducer keys and pressing the next key until the display shows the transducer...

Page 21: ...minutes without use This mode still uses battery power so best to turn the meter off if not used for any length of time Press the clear key to resume operation when the power down mode is active depic...

Page 22: ...8 ounces Stand Folding and adjustable bench wall or shelf stand supplied standard Memory Up to 1 350 torque data Includes data number torque value and units Communication Direct to serial computer or...

Page 23: ...eter beeps when pressing save button 1 There may be a load on the transducer when power was turned on Remove load and press Zero Tare or Remove load and turn meter off then on 1 Memory is full Clear M...

Page 24: ...3 Keypad 810043 2 PCB Assembly 810044 LCD 810023 Battery 9 Volt 45 0001 Stand Adjustable 810046 Cable Rs232 065150 Adapter Serial RJ6 Rs232 772084 Power Supply 9V 300mAh 97 0002 Cable Transducer up t...

Page 25: ...protective boot Dallas Semiconductor 2430 2 wire memory chip installed in each transducer programmed with the following data CW mv v at full scale and 10 of full scale CCW mv v at full scale and 10 of...

Page 26: ...rt Number BM 2000F 1 x 1 85 0117 BM 1000F 1 x 1 BM 600F 3 4 x 3 4 85 0103 BM 500F 3 4 x 3 4 BM 250F x 85 0098 BM 100F 3 8 x 3 8 85 0097 BM 50F 3 8 x 3 8 BM 250i 1 4 x 3 8 85 0120 BM 100i 1 4 x 1 4 85...

Page 27: ...275 6 1 4 1 4 x 1 4 BMI 250 2 75 2 6 2 175 275 6 3 8 3 8 x 3 8 BMF 50 2 75 2 6 2 175 275 1 0 3 8 3 8 x 3 8 BMF 100 4 0 3 6 3 0 44 2 7 1 2 x 1 2 BMF 250 4 0 3 6 3 0 44 2 8 1 2 x 1 2 BMF 500 4 0 3 6 3...

Page 28: ...re at a later date Do not use a transducer if it has been over torqued Never apply torque in a situation where tool breakage may result in a fall or slip resulting in personal injury Pulling on the wr...