2D1 – PRESSURE RINSE AID DISPENSER
This unit does not use a pressure rinse-aid dispenser.
2D2 – PERISTALTIC RINSE AID AND DETERGENT DISPENSER
Setting of rinse aid dispenser is done after removal of front panel, under the tank door.
1- Close gently all the way down the dispenser by screwing anticlockwise the setting screw of the dispenser.
2- Open up until reached necessary quantity by screwing clockwise the potentiometer of the dispenser.
(Fig.11)
Fig.11
Quantity for the first setting should be according to the installation after evaluating the hardness of the
water and the type of rinse aid used. Recommended rinse aid standard quantity is 0,16 gr/sec that
correspond to the maximum flow rate of the dispenser.
Recommended detergent standard quantity is 0,77 gr/sec that correspond to the maximum flow rate of the
dispenser.
SUGGESTION
To check the effectiveness of the rinse aid, look at freshly washed glasses against the light. Drops of water
remaining on the glass indicate an insufficient amount while streaks indicate an excess.
2D3 – DISHWASHERS WITHOUT DETERGENT DISPENSER