BOOSTER TEMPERATURE PROBE
Booster temperature probe not connected or faulty.
Verify that the probe is correctly and well connected to the electronic board.
Verify that the probe is correctly positioned inside the booster and there is not presence of limestone on it.
ntcu
E-02
TANK TEMPERATURE PROBE
Tank temperature probe not connected or faulty.
Verify that the probe is correctly and well connected to the electronic board.
Verify that the probe is correctly positioned inside the tank and there is not presence of limestone on it.
fill
E-03
WATER FILL
Water fill not completed during the available maximum time (10min).
Verify that water supply is correctly connected, opened and free of obstructions.
Verify that solenoid valve filter is free of possible obstructions and deposit.
Verify that water supply pressure is adequate (par.1D – Technical Data).
Verify that machine’s door is completely closed and the overflow device is correctly positioned inside the
tank.
N.B.
If water fill timing expires or in case of water level signal is not respected solenoid valve is automatically
interrupted. To restart solenoid valve press any button on the control panel.
Tbo
E-04
BOOSTER TEMPERATURE LIMIT
Booster temperature maximum set point reached (set point +14°C / 57°F).
SUBSTITUE THE ELECTRONIC BOARD
TUA
E-05
TANK TEMPERATURE LIMIT
Tank temperature maximum set point reached (set point +7°C / 44°F).