Installation 727 , continued
ELECTRICAL
ELECTRICAL
A 208-240 volt, 60 Hz, Single Phase circuit is required for
this unit. Check the rating plate on the front of the machine
for the amp draw. In spite of the fact that the rating plate
shows 208 volts, the unit is designed function properly on
208 volts to 240 volts.
The top & back panels must be removed for the electrical
hook -up. The top panel is secured by two Phillips head
screws. Once the screws are removed, the panel should be
slid to the back and lifted. The back panel is also held by
two screws. Remove them, pull the bottom away from the
machine and lift the panel.
G
The terminal block is located inside the back cover. Pass
the cable through the cable strain relief and connect the
wires to the terminals L1 (brown wire), L2 (blue wire) &
Ground (yellow & green wire). Replace the top & back
L1
Water
panels being careful not to pinch or kink any wires or hoses.
There should be sufficient cable length to G
Allow the machine to be pulled out for service.
IMPORTANT NOTE
Reasonable access to and around the machine for service
must be provided. Disconnecting of hard plumbing or
removal of counter tops or cabinets, etc., for servicing is not
covered by warranty.
DO NOT fill dishwasher manually with water. The
dishwasher will fill automatically when the power is turned
on.
All panels must be replaced on the unit when the
installation
L2
Water In
Out
8