WARNING MESSAGES DISPLAYED ON THE CONTROL PANEL
NOTE: If the machine is in OFF mode, warning messages are not displayed. Turn ON
the machine to see the Error Message..
ERROR MESSAGES
TEMPERATURE PROBE
Booster temperature probe damaged or not connected.
CALL TECHNICAL SERVICE ASSISTANCE
TANK TEMPERATURE PROBE
Tank temperature probe damaged or not connected.
CALL TECHNICAL SERVICE ASSISTANCE
WATER FILLING
Water filling process not completed on time (max 10min).
Verify inlet main water supply is correctly connected, open and free from any
obstructions.
Verify solenoid valve filter is free from any obstructions such as lime or scale.
Verify inlet water pressure corresponds to the Technical Data.
Verify the door is closed and the water flow device is correctly positioned.
N.B.
If water filling time limit expires or filling water level is lost, the solenoid valve closes
automatically the inlet water. To reset and restart the solenoid valve press any button on
the control panel.
BOOSTER TEMPERATURE LIMIT
CALL TECHNICAL SERVICE ASSISTANCE
TANK TEMPERATURE LIMIT
CALL TECHNICAL SERVICE ASSISTANCE
DRAIN ANOMALY
Drain anomaly, water draining not completed during the time limit.
Verify water flow device is removed and water drain line is free from any obstructions.
BOOSTER HEATING
Maximum booster heating time passed the limit. (15min)
CALL TECHNICAL SERVICE ASSISTANCE
TANK HEATING
Maximum tank heating time passed the limit. (30min)
CALL TECHNICAL SERVICE ASSISTANCE
PARAMETER ERROR OR ELECTRONIC CARD FAILURE
Electronic card anomaly or failure.
CALL TECHNICAL SERVICE ASSISTANCE FOLLOWING ACTIONS AFTER
MACHINE ERROR OR BREAKDOWN:
Booster and tank heating elements are interrupted, water load is disactivated, control
panel display visualizes the error and the electronic card is inactivated. All led buttons
are OFF. Washing cycle is interrupted (standby mode) and restored if the problem is
solved. It is always possible to turn OFF the machine by pressing button “A” ON/OFF,
and if the problem is solved, warning messages are not more displayed.
15
BOOSTER TEMPERATURE PROBE
TANK TEMPERATURE PROBE
WATER FILLING
BOOSTER TEMPERATURE LIMIT
TANK TEMPERATURE LIMIT
DRAIN ANOMALY
BOOSTER HEATING
TANK HEATING
PARAMETER ERROR