EASYPOOL SMART 0 Operating Manual | 9
Installation and Commissioning
5. Installation and Commissioning
5.1 Tools required
The following tools are required to set up the water sampling
station:
Drill machine with 8 mm masonry drill
Open-end spanner set 10-7 mm
Suitable cutter
Flat tip and Philips screwdrivers
3 and 4 mm Allen key
PTFE tap, sealant for injection nozzle
5.2 Wall mount
The following criteria must be taken into account when selecting
the assembly location:
Level surface
Water sampling station moves out to the left.
The assembly height must be selected so that the operator
can easily fit the sensors to the top of the station. The con-
troller display should be in lie with the eyes of the operator.
Above the station there must be at least 5 cm free space
to handle the glass electrodes.
Below the water sampling station there must be at least 0
cm free space to route the hoses.
No damp-sensitive components below the water sampling
station
A damp room SCHUKO socket outlet with continuous cur-
rent, max. 1.5 m away.
All hoses and cables must be routed without twists.
No hose line longer than 5 m.
Avoid direct sunlight or heat radiation.
Unscrew the wall bracket from the water sampling station and fit
it to the wall. The screws supplied are suitable for masonry. The
left side of the wall bracket must be aligned vertically with a spirit
level. After assembly, put the water sampling station back in the
wall bracket and attach the hinges.
5.3 Electrical connection
All work on the electrical installation must only be carried out by
authorised and qualified electricians.
The water sampling station is pre-wired. The device is equipped
with a mains connector. The 30 V socket must be protected with
max. 5 A fuse.
NOTICE!
The device must be supplied with continuous cur-
rent. The logical locking with the filter controller is
performed via control contacts as required. When the
water is not moving the controller automatically inter-
rupts dosing.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
NOTICE!
Only work on electrical connections while the device
is disconnected from the power supply.
For all other connections refer to the device details
for the con-
troller.
5.4 Connection to the pool water circuit
NOTICE!
Before working on the pipeline system switch off the
bathing water circulation and close the valves before
and behind the installation location. Secure the sys-
tem against accidental power-up.
a
g
e
d
c
b
f
h
Fig. 5.4.1: Functional diagram of a swimming pool water system with an
overflow channel
a
Swimming pool
b
Splash water tank
c
Circulation pump
d
Filter
e
Sample water removal
e
Sample water return
g
Injection nozzles for disinfectant and pH-adjusting solution
h
Sample water filter
For swimming pools with a splash water tank the sample water
is removed directly from the pool, approx. 0 cm below the water
surface. For pools without a splash water tank it is between the
circulation pump and filter.