Start Up | Operation Manual C 2213 |
17
Dosing rate
DN 8
DN 12
DN 15
[kg Cl
2
/h]
Hose 8/12
Hose 12/16
Pipe d 20
[m]
1
160
1100
4500
2
50
300
950
3
25
160
450
4
14
100
280
5
9
65
190
7,5
-
30
90
10
-
20
55
Tab.: 3: Maximum length for vacuum lines
The total value of the chlorine gas flow is decisive for the line dimensioning. If for example the line is divided
into two lanes directly in front of the ejectors, the long lane must be dimensioned considering the whole
chlorine gas flow.
100m
2kg/h
1kg/h
Fig. 10: Installation example vacuum line
In this example the long distance is carried out in DN12, and for the relatively short unit connections a 8/12
PE-tube is used.