COMPONENT ACCESS
JennAir Built-in Coffee System
n
4-17
Removing the Steam Heater and 3-Way Valve
1.
Complete the steps
from
“Removing the Back Panel and
Side Panel”
, prior to performing the following steps.
2.
With the help of 10 mm wrench remove the two hoses
connected to the inlet and outlet of the steamer.
3.
Remove the three hoses by removing the fixing-clips from the
3-way solenoid valve located on the back of the steamer.
4.
Remove the two screws which are securing the steamer
bracket.
5.
Remove the cable connections from the steamer. In this way,
the steamer can be easily removed from the appliance.
6.
Unscrew the two (2) screws securing the 3-Way solenoid
valve to the bracket.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.