COMPONENT ACCESS
4-24
n
JennAir Built-in Coffee System
Removing the 2-Way Solenoid Valves
2-Way Solenoid Valves (Hot Water)
1.
Complete the steps
from
“Removing the Top Panel and
Fan Panel”
.
2.
Complete the steps
from
“Removing the Back Panel and
Side Panel”
, prior to performing the following steps.
3.
Remove the fixing clips of the two hoses of solenoid valve.
Disconnect hoses and power supply cables from the 2-way
solenoid valves (hot water).
4.
Remove the two screws which are securing the body of 2-way
solenoid valve (hot water) to the support.
5.
Remove 2-way solenoid valves (hot water).
2-Way Solenoid Valves (Steam)
1.
Complete the steps
from
“Removing the Top Panel and
Fan Panel”
.
2.
Complete the steps
from
“Removing the Back Panel and
Side Panel”
, prior to performing the following steps.
3.
Remove the fixing clips of the two hoses of solenoid valve.
Disconnect hoses and power supply cables from the 2-way
solenoid valves (steam).
4.
Remove the two screws which are securing the body of 2-way
solenoid valve (steam) to the support.
5.
Remove 2-way solenoid valves (steam).
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
2-Way Solenoid Valve (Hot Water)
2-Way Solenoid Valve (Hot Water)
2-Way Solenoid Valve (Steam)
2-Way Solenoid Valve (Steam)