9
Step 6:
Place 9.2k burner choke(s) into right rear and
left front orifice holder with chamfer facing down. (See
figure 10).
FIGURE 10
Step 7:
Place 15k burner choke into center orifice
holder. (See figure 11).
Step 8:
Replace burner base, caps, and grates.
Tighten screws (do not cross thread) to 25-30 in lbs.
Step 9:
Save the orifices removed from the appliance
for future use.
FIGURE 11
B. INVERT CAP IN APPLIANCE PRESSURE
REGULATOR
(See figure 12)
With the appliance installed, the appliance regulator
should be located as shown in figure 3 or 4.
CONVERSION OF APPLIANCE PRESSURE
REGULATOR
FIGURE 12
C. LOW FLAME ADJUSTMENT
(See figure 13)
This appliance is shipped from the factory with low and
high flame settings adjusted for use with natural gas.
To set for use with LP proceed as follows:
1. Remove control knob from valve stem.
CAUTION:
NEVER USE A METAL BLADE TO
PRY KNOB OFF. IF KNOB CANNOT BE EASILY
REMOVED, TUCK THE FOLDS OF A CLOTH
DISHTOWEL UNDER THE KNOB AND PULL THE
TOWEL UPWARD WITH STEADY, EVEN PRES-
SURE.
2. Carefully remove rubber grommet.
3. Locate the valve adjustment screw. See figure 13.
4. Insert a slender, thin-blade screwdriver into knob
hole and engage blade with slot in adjusting screw.
5. Turn the adjusting screw clockwise until tight (5-7
in-lbs max.). Do not over tighten.
6. Replace rubber grommet and control knob.
7. Repeat for remaining burners.
FIGURE 13
VIEW THROUGH KNOB HOLE