10
After the above operation, the burner will produce a
stable, steady blue flame of minimum size. The setting
should be checked by turning knob from high to low
several times without extinguishing the flame.
The above operation will automatically provide the proper
flame size at medium setting.
After Conversion Steps A, B and C have been completed,
check the appearance of each burner flame at the Hi and
Lo settings against figure 14. If the flames appear too
large or too small, review each step to make sure it was
completed correctly.
FIGURE 14
FLAME APPEARANCE AT HI AND LO
To Convert Appliance For Use
With Natural Gas
Electrical power and gas must be turned off
prior to conversion.
If this appliance has been converted for use with LP gas,
each of the following modifications must be performed to
convert the unit back to natural gas.
A. REPLACE ALL ORIFICE SPUDS.
1. Perform Steps 1 and 2 on page 8.
2. Remove chokes from the left front, center and right
rear orifice holder (see figures 10 and 11). As
required a simple paper clip can be used to remove
the left front and right rear choke.
3. Perform Step 3 on page 8.
4. For Step 5: Locate the brass natural gas orifice
spuds that were originally installed in this appliance
before its conversion for use with LP gas. Observe
the number on each of the spuds and note the
correct burner location for each spud as shown in
figures 15 and 16.
FIGURE 15
Installation Of Natural Gas Orifice Spuds
5 BURNER MODEL (36
²
WIDE)
FIGURE 16