Jenn-Air JGC9430 Installation Manual Download Page 11

11

5. Complete Steps 5, 8 and 9 on pages 8 & 9 to

complete the installation of natural gas main spuds
in their correct locations.

6. Save the orifices & chokes removed from the

appliance for future use. They will be needed if this
appliance is again converted for use with LP gas.

C. INVERT CAP IN APPLIANCE PRESSURE

REGULATOR.

(See figure 12).

With the appliance installed the appliance regulator
should be located as shown in either figure 3 or figure 4
(pages 4 & 5). Identify the type of appliance regulator
and follow the instructions in the appropriate illustration.

D. RESET THE VALVES FOR NATURAL GAS

1. Light one burner, and set on low.

2. Remove the knob.

3. Remove the rubber grommets.

4. Locate the valve adjustment screw. See figure 13.

5. Insert a slender, thin-blade screwdriver into knob hole

and engage blade with slot in adjusting screw.

6. Starting from the LP position (see #5 on page 9, under

C. LOW FLAME ADJUSTMENT), turn the screw
counter clockwise until the flame stabilizes and
matches the pictured “low” setting on figure 14. Proper
adjustment will produce a stable, steady blue flame of
minimum size. The final adjustment should be checked
by turning the knob from high to low several times
without extinguishing the flame.

After Steps A, B and C have been completed, check
the appearance of each burner’s flame at the Hi and Lo
settings against figure 14. If the flames appear too
large or too small, make sure all steps were completed
correctly.

JENN-AIR 30

²²²²

INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)

FIGURE 17

BURNER LOCATION

Hi

Lo

Right Front

15,000 / 15,000

2000 / 2000

Right Rear

9,200 / 9,100

1450 / 1550

Left Front

5,000 / 4,000

650 / 850

Left Rear

10,500 / 9,100

1450 / 1550

Burner Ignition And
Auto-Reignition

This appliance is equipped for electronic auto-reignition by
means of a spark igniter located at the rear of each
burner. The burners are designed to light at any valve
rotation that admits sufficient gas flow to support a flame
and to automatically relight following a loss of flame due
to a draft or other adverse condition. This feature is
provided as a convenience and is not intended as a safety
feature.

CAUTION:

Never cover control knobs or surrounding

control surface with utensils, towels, or other objects.
Never obstruct free air passage past the control knobs.
The knob openings have been sized to properly control air
entry to the interior of the appliance during operation.

This appliance has no air shutters. Primary air
adjustments are unnecessary. The burners are designed
to provide optimum aeration for all gases without air
shutters. When operating properly, burners should
produce clearly defined, even blue flames. If the flames
have yellow tips or are hazy and otherwise appear to
have insufficient air, obtain the services of a qualified
service technician. Some yellow tipping on LP gas is
normal.

Specified input rates are as shown in figures 17 and 18.

JENN-AIR 36

²²²²

INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)

FIGURE 18

5 BURNER MODEL

BURNER LOCATION

Hi

Lo

Right Front

12,500 / 10,500

1450 / 1600

Right Rear

5,000 / 4,000

650 / 850

Left Rear

5,000 / 4,000

650 / 850

Left Front

9,200 / 9,100

1450 / 1550

Center

17,000 / 15,000

2000 / 2000

Summary of Contents for JGC9430

Page 1: ...AL WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE MAINTENANCE OR USE OF RANGE CAN RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE NOTICE TO INSTALLER Leave these instructions with the applian...

Page 2: ...f the countertop laminate 4 Countertop must be supported within 3 7 62 cm of cutout Installing Cabinetry Over Your Jenn Air Cooktop A 30 76 2 cm minimum vertical clearance between cooking surface and...

Page 3: ...d a length of three 3 feet 36 inches All supply piping except as noted should use common National Pipe Thread N P T For all pipe connections use an approved pipe joint compound resistant to the action...

Page 4: ...e appliance in its counter cutout Make the gas connection to the inlet of the appliance pressure regulator with 1 2 NPT male pipe threads Install a manual shut off valve in an accessible location in t...

Page 5: ...an accessible location in the gas line ahead of the appliance regulator and external to the appliance for the purpose of turning on or shutting off gas to the appliance Make additional pipe connectio...

Page 6: ...ubbles appearing around fittings and connections will indicate a leak If a leak appears turn off supply line gas shut off valve tighten connections turn on the supply line gas shut off valve and retes...

Page 7: ...elf If the outlet is to be mounted in either a left or right adjacent cabinet a clearance hole as described above must be provided in the dividing wall between the cabinets Figure 4 page 5 illustrates...

Page 8: ...d C A REPLACE ALL ORIFICE SPUDS Step 1 Remove the grates and burner caps Step 2 Remove burner base by removing 2 screws See figure 7 Step 3 Firmly press 9 32 or 7mm nut driver over the orifice spud fi...

Page 9: ...W FLAME ADJUSTMENT See figure 13 This appliance is shipped from the factory with low and high flame settings adjusted for use with natural gas To set for use with LP proceed as follows 1 Remove contro...

Page 10: ...ower and gas must be turned off prior to conversion If this appliance has been converted for use with LP gas each of the following modifications must be performed to convert the unit back to natural g...

Page 11: ...NATURAL GAS LP GAS BTU HR FIGURE 17 BURNER LOCATION Hi Lo Right Front 15 000 15 000 2000 2000 Right Rear 9 200 9 100 1450 1550 Left Front 5 000 4 000 650 850 Left Rear 10 500 9 100 1450 1550 Burner I...

Page 12: ...est equipado para el tipo de gas que se suministrar Consulte la placa de datos que se encuentra en el lado de abajo de la caja de los quemadores para obtener esta informaci n No trate de convertir est...

Page 13: ...e la cocina debe estar apoyado a menos de 3 7 62 cm del corte del hueco Instalaci n de los gabinetes por encima de la superficie para cocinar Jenn Air A 30 76 2 cm de espacio vertical m nimo entre la...

Page 14: ...Toda la tuber a de suministro excepto seg n se especifique deber usar tuber a de rosca est ndar National Pipe Thread NPT En todas las conexiones de la tuber a use un compuesto de uniones aprobado que...

Page 15: ...2 NTP Instale una v lvula de cierre manual en un lugar accesible en la tuber a de gas m s adelante del regulador de presi n y afuera del electrodom stico con el fin de cerrar y abrir el gas al aparato...

Page 16: ...ierre a la fuente del suministro de gas Aseg rese de que todas las conexiones de uni n de la tuber a est n a prueba de gas FIGURA 4 ILUSTRACI N DE LA TUBER A DEL SUMINISTRO DE GAS HORNO DE PARED INSTA...

Page 17: ...a fuga cierre la v lvula de la tuber a de suministro de gas apriete las conexiones abra la v lvula de cierre de la tuber a de gas y vuelva a revisar si hay fugas Nunca revise si existen fugas con una...

Page 18: ...te adyacente izquierdo o derecho debe proveerse un orificio libre como se describe anteriormente en la pared divisoria entre los gabinetes La figura 4 p gina 5 ilustra una pared divisoria t pica lado...

Page 19: ...figura 7 Paso 3 Oprima con firmeza una llave para tuercas de 9 32 7 mm sobre los puntales de orificio figura 7 y afloje los puntales gir ndolos en sentido contrario al de las manecillas del reloj Leva...

Page 20: ...OS BORDES DEL DISCO PARA VOLVER A COLOCAR EL PASADOR EN LA TAPA APLIQUE PRESI N HACIA LOS LADOS CON EL DEDO PARA QUITAR EL PASADOR DE LA TAPA TAPA Y PASADOR DEL CONVERTIDOR C AJUSTE DE LA LLAMA BAJA V...

Page 21: ...ERTENCIA Si este electrodom stico se ha convertido para usarse con gas LP deben realizarse cada una de las siguientes modificaciones para convertir la unidad de nuevo a gas natural A COLOQUE DE NUEVO...

Page 22: ...0 Posterior derecho 9 200 9 100 1450 1550 Delantero izquierdo 5 000 4 000 650 850 Posterior izquierdo 10 500 9 100 1450 1550 Encendido del quemador y reencendido autom tico Este electrodom stico est e...

Page 23: ...USAGE INCORRECT PEUVENT ENTRA NER DES BLESSURES OU DES D G TS GRAVES L INTENTION DE L INSTALLATEUR VEUILLEZ LAISSER CES INSTRUCTIONS AVEC L APPAREIL L INTENTION DU CONSOMMATEUR VEUILLEZ CONSERVER CET...

Page 24: ...us du comptoir doit avoir un support une distance maximum de 3 po 7 6 cm des rebords de la d coupe Pose d armoires au dessus de la plaque de cuisson Jenn Air A 30 po 76 2 cm minimum entre la plaque de...

Page 25: ...sur la conduite de gaz de cet appareil Quand un raccord flexible de gas est utilis il ne doit pas exc der une longueur de trois 3 pieds 36 pouces 91 4 cm Sauf indication contraire toutes les conduites...

Page 26: ...e 1 2 po NPT 13 mm Poser un robinet d arr t dans un endroit accessible de la conduite de gaz en amont du d tendeur et ext rieure l appareil afin de pouvoir fermer ou ouvrir l alimentation en gaz de l...

Page 27: ...n en gaz de l appareil Effectuer toutes connexions de conduite suppl mentaires en amont du robinet d arr t de l alimentation en gaz S assurer que tous les raccords sont bien serr s I M P O R T A N T A...

Page 28: ...es apparaissent autour des joints et des raccords il y a une fuite En cas de fuite fermer le robinet d alimentation de gaz serrer les raccords ouvrir le robinet de gaz et rev rifier s il y a des fuite...

Page 29: ...i re de la tablette Si la prise doit tre mont e dans une armoire adjacente gauche ou droite un trou comme celui d crit ci dessus doit tre pratiqu dans la cloison entre les armoires La figure 4 page 5...

Page 30: ...retiennent en place Voir la figure 7 tape 3 Pousser fermement un tourne crou de 9 32 po ou 7 mm sur les raccords orifice figure 7 et desserrer le raccord en le tournant dans le sens anti horaire Reti...

Page 31: ...ER DES DOIGTS SUR LES BORDS DU DISQUE POUR REMETTRE LA BROCHE DANS LE CAPUCHON FAIRE PRESSION SUR LE C T DU BOUT DES DOIGTS POUR ENLEVER LA BROCHE DU CAPUCHON GPL GPL C R GLAGE DE LA FLAMME DE MIJOTAG...

Page 32: ...lectricit avant de proc der la conversion AVERTISSEMENT Si cet appareil a t converti au GPL chacune des modifications suivantes doit tre effectu e pour le reconvertir au gaz naturel A REMPLACER TOUS...

Page 33: ...eu doux Avant droit 15 000 15 000 2 000 2 000 Arri re droit 9 200 9 100 1 450 1 550 Avant gauche 5 000 4 000 650 850 Arri re gauche 10 500 9 100 1 450 1 550 Allumage standard et allumage automatique d...

Reviews: