Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
14 16026926
© 2006 Maytag Services
Illustration Component
Test
Procedure
Results
Convection motor,
2-speed
Measure voltage ....................................
Check motor windings to ground............
120 VAC. (tolerance: 105 to 135 VAC).
No continuity.
RPM, Lo-speed:
Approx. 1440 to 2040.
RPM, Hi-speed:
Approx. 1860 to 2460.
(JES8750BA*)
Oven limit switch
Normally closed, verify operation:
Open:
208° to 222° F (98° to 105° C)...
Closed:
156° to 174° F (69° to 79° C) ..
Infinite.
Continuity.
(JES8850B**)
Oven limit switch
Normally closed, verify operation:
Open: 130° to 140° F (54° to 60° C).......
Closed: 109° to 121° F (43° to 50° C) ....
Infinite.
Continuity.
(JES9860B**,
JES9800BA*,
JES9900B**)
Oven limit switch
Normally closed, verify operation:
Open: 209° to 221° F (98° to 105° C).....
Closed: 144° to 166° F (62° to 74° C) ....
Infinite.
Continuity.
(JES9750BA*)
Oven limit switch
Normally closed, verify operation:
Open: 208° to 222° F (98° to 105° C).....
Closed: 156° to 174° F (69° to 79° C) ....
Infinite.
Continuity.
Hi-limit temperature
switch
(Warming Drawer)
Normally closed, verify operation:
Open:
135° to 145° F (57° to 63° C).....
Closed:
114° to 126° F (46° to 52° C) ..
Infinite.
Continuity.
Hi-limit temperature
switch
(Warming Drawer)
Normally closed, verify operation:
Open:
95° to 105° F (35° to 41° C).......
Closed:
79° to 91° F (26° to 33° C)......
Infinite.
Continuity.
Ribbon element, 1200 W
Disconnect wiring to element and
measure cold resistance of terminals. ....
Measure voltage at element ...................
Approx. 44 to 49
Ω
.
240 VAC.
Ribbon element, Dual,
2400 W (1200 W inner,
1200 W outer)
Disconnect wiring to element and
measure cold resistance of terminals. ....
Measure voltage at element ...................
Inner:
Approx. 44 to 49
Ω
.
Outer:
Approx. 44 to 49
Ω
.
240 VAC.
Ribbon element, Dual,
3000 W (1400 W inner,
1600 W outer)
Disconnect wiring to element and
measure cold resistance of terminals. ....
Measure voltage at element ...................
Inner:
Approx. 38 to 42
Ω
.
Outer:
Approx. 34 to 37
Ω
.
240 VAC.
Ribbon element, Triple,
3000 W (1000 W inner,
2000 W middle
2700 W outer)
Disconnect wiring to element and
measure cold resistance of terminals. ....
Measure voltage at element ...................
Inner:
Approx. 52 to 57
Ω
.
Middle:
Approx. 25 to 29
Ω
.
Outer:
Approx. 19 to 24
Ω
.
240 VAC.
Summary of Contents for JES8750BA Series
Page 50: ...B 2 16026926 2006 Maytag Services Use Care Information ...
Page 51: ... 2006 Maytag Services 16026926 B 3 Use Care Information ...
Page 52: ...B 4 16026926 2006 Maytag Services Use Care Information ...
Page 53: ... 2006 Maytag Services 16026926 B 5 Use Care Information ...
Page 54: ...B 6 16026926 2006 Maytag Services Use Care Information ...
Page 55: ... 2006 Maytag Services 16026926 B 7 Use Care Information ...
Page 56: ...B 8 16026926 2006 Maytag Services Use Care Information ...
Page 57: ... 2006 Maytag Services 16026926 B 9 Use Care Information ...
Page 58: ...B 10 16026926 2006 Maytag Services Use Care Information ...
Page 59: ... 2006 Maytag Services 16026926 B 11 Use Care Information ...
Page 60: ...B 12 16026926 2006 Maytag Services Use Care Information ...
Page 61: ... 2006 Maytag Services 16026926 B 13 Use Care Information ...
Page 62: ...B 14 16026926 2006 Maytag Services Use Care Information ...
Page 63: ... 2006 Maytag Services 16026926 B 15 Use Care Information ...
Page 64: ...B 16 16026926 2006 Maytag Services Use Care Information ...
Page 65: ... 2006 Maytag Services 16026926 B 17 Use Care Information ...
Page 66: ...B 18 16026926 2006 Maytag Services Use Care Information ...
Page 67: ... 2006 Maytag Services 16026926 B 19 Use Care Information ...