5-2
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Refer to page 4-15 for the procedure for ac-
cessing the thermistor.
1. Unplug refrigerator or disconnect power.
2. Disconnect the thermistor connector from
the wiring harness.
3. Set the ohmmeter to the R x 10 scale.
4. Touch the ohmmeter test leads to the
connector pins. The meter should indi-
cate as shown in the chart.
NOTE:
If the resistance of the thermistor is
normal, perform the following voltage test.
5. Set the voltmeter to read a maximum
voltage of 10 volts DC.
6. Attach meter leads to Thermistor har-
ness.
TEMP
RESISTANCE
TEMP RESISTANCE
(
°
F)
Ω
(APPROX.)
(
°
F)
Ω
(APPROX.)
–5
25900-27500
45
5930-6300
0
22100-23500
50
5190-5510
5
18900-20000
55
4550-4830
10
16200-17200
60
4000-4240
15
13900-14800
65
3520-3730
20
12000-12800
70
3100-3300
25
10400-11000
75
2740-2910
30
8990-9550
80
2430-2580
32
8750
85
2160-2290
35
7800-8290
90
1920-2030
40
6800-7220
7. Connect power to the refrigerator and al-
low it to enter the “cooling” mode. With
the refrigerator in the cooling mode, The
meter should indicate approximately 5
volts DC.
8. Unplug refrigerator or disconnect power.
9. Connect Thermistor and install
10. Plug in refrigerator or connect power
THERMISTOR
COMPONENT SPECIFICATIONS
Summary of Contents for JB36NXFXLW00
Page 7: ...1 3 BOTTOM MOUNT FEATURES JB36NXFXLW00 JB36NXFXRW00 ...
Page 8: ...1 4 FRENCH DOOR FEATURES JF42NXFXDW00 ...
Page 9: ...1 5 SIDE BY SIDE FEATURES ...
Page 10: ...1 6 NOTES ...
Page 44: ...3 10 42 and 48 Integrated SXS Cabinet Air Flow Schamatic AIR CIRCULATION continued ...
Page 46: ...3 12 NOTES ...
Page 72: ...4 26 NOTES ...
Page 83: ...6 4 NOTES ...
Page 91: ......