Subject to change without notice!
User Manual ECOSTEP®54
43
9.1.5
Operation mode 3 (Profile Velocity Mode)
Flowchart velocity mode (3) for ECO54 axis,
Stauts: control word = 0x0006, status word = 0x0031
For safety reasons every movement of an axis should be monitored by the PLC via timeout. The relevant
parameter target_velocity cannot be manipulated by the PLC if a mapping to other controller parameters (analog
input, etc.) exists!
no
yes
yes
no
nein
no
yes
no
yes
yes
no
yes
no
The objects to be written or to be read, resp. for the individual axes are (incl. sub index and length):
Axis 0
Axis 1
Axis 2
Axis 3
control word
60400010
68400010
70400010
78400010
status word
60410010
68410010
70410010
78410010
target_velocity
60FF0020
68FF0020
70FF0020
78FF0020
modes_of_operation
60600008
68600008
70600008
78600008
profile_acceleration
60830020
68830020
70830020
78830020
profile_deceleration
60840020
68840020
70840020
78840020
control word = 0x000F
Set
target_velocity = 0x00000000
and
modes_of_operation = 0x03
einstellen
Drive operates,
status word = 0xX537 ?
Optional:
profile_acceleration =
0xXXXXXXXX;
profile_deceleration =
0xXXXXXXXX;
Modify velocity?
Stop drive?
target_velocity = 0x000
Continue drive operation?
Drive stopped,
status word = 0xX437 ?
Error
Error
target_velocity = 0xXXXXXXXX;
Switch off drive?
control word = 0x0006