5.2
Electrical Installation
5.2.1
Important notes
All installation work may only be carried out if the machine or plant is not live and protected against re-
start.
Never exceed the maximum rated voltage at the connector X11 (power supply) X11!
U
max
= 45V
DC
Th e guarding of the DC supply and the 24 V logic voltage should be carried out by the user
Stepper motor amplifi er and motor have to be properly grounded. Th e protective earth conductor must
have at least the same diameter as the supply cables. Th e stepper motor amplifi er should be mounted onto a
conductive (not varnished) metal mounting plate.
5.2.2
EMC compliant installation
Th e supply connection of the machine should be equipped with an appropriate RFI suppression fi lter. Al-
ways use shielded cables. Metal parts in the cabinet have to be interconnected extensively and and be con-
ductive regarding HF. Used relays, contactors, solenoids etc. have to be protected against overvoltage. Supply
cables and motor cables must be laid in a proper distance of control cables.