7 - 21
• (1) Execution Monitor
1)When the program starts, the following monitor appears.
Note: If the download file is correct, "VCF420" appears on the top line (See Fig-43).
Fig-43
(2)
Commands:
Use letter keys to enter a command.
I:
Addressed Reset - Reset a selected unit in the machine.
V:
Version Information Request - Read the program version after downloading completed.
G:
Global Reset - Reset all the units (including EBA) connected to the machine.
[Ctrl]-x:Abort - Exit the program
F:
File Download - Download the specified file.
P:
Program Check Verify - Check CRC by EBA itself.
[Ctrl]-f:File Download (Selection) - DO NOT USE THIS COMMAND!
S:
Set Start Addr. & Seed Val. - Set the start address and initial value of CRC when checking
CRC.
CHAPTER 7
Downloading software to Flash Memory
Dev.=f0 Port1 File=xxxx.xxx VCF420:00C00000:00C7FFFF CRC3173 38400bps RUN
DOWN LOAD PROGRM Ver.214-00 05/JUN/'03 JCM
I:Addressed Reset
V:Version Information Request
G:Global
Reset
Ctrl-X:Abort
F:File Download
P:Program Check Verify
S:Set Start Addr. & Seed Val.
Ctrl-f:File Download (Section) (Start Addr,:000000 Seed Val.:0000)
Device Ver.:
Validator Status:
Selected serial port NO.
Entered download filename.
If the download file is for the EBA-3x series, "VCF420" appears.