7 - 15
CHAPTER 7
Calibration
9)
Then the following message will appear (See Fig-33). Insert the black reference paper to the EBA-30/32
/34
unit
and then press the [Next] button to start the Black level check.
Fig-33
10) When complete the Black level check, the following message will appear (See Fig-34). Remove the black
reference paper from the EBA-30/32
/34
unit and close the acceptor head cover properly. Then click [Next]
button to start Without paper adustment.
Fig-34