7 - 3
(5)
DIP Switch (on side)
Used for I/F selection. Refer to the table below for appropriate settings.
Be sure to set the switches prior to power-up.
(6) Reset Switch (on side)
Hard reset switch
Effective only for EBA-32/33
1-3
LED (total 13 LEDs)
(1) POWER
Lights when the VM30 power is on.
(2) DIR
(3) SICLK
(4) SETLD
These 3 LEDs display the communication status with a parallel I/F conversion board (to be
developed). The LEDs flash in case of “Acceptor I/F Output Test” during test mode.
(5) MODE DISPLAY 1 - 5
LEDs for external display (ex. Faceplate). These LEDs are enabled by connecting the unit to the
MODE SIG IN connector.
(6) MDB TXD
Indicator of the transmission status of acceptor’s ID-0D3 (MDB) I/F. It lights / flashes during
“Acceptor I/F Output Test” and “Acceptor I/F Input Test” of test mode.
(7) CCT TXD
Indicator of the transmission status of acceptor’s ID-0E3 (ccTalk) I/F. It lights / flashes during
“Acceptor I/F Output Test” and “Acceptor I/F Input Test” of test mode.
(8) HII TXD
(9)
HII TALK
Indicator of the transmission status of acceptor’s ID-0F3 (HII) I/F. These LEDs light / flash during
“Acceptor I/F Output Test” and “Acceptor I/F Input Test” of test mode.
CHAPTER 7
VM-30 Descriptions
ID-003 I/F
MDB I/F
CCTALK I/F
HII I/F